Human DβH (Dopamine-β-Hydroxylase) CLIA Kit (E-CL-H0797)

Human DβH (Dopamine-β-Hydroxylase) CLIA Kit - 1
  • Human DβH (Dopamine-β-Hydroxylase) CLIA Kit - 1
  • Human DβH (Dopamine-β-Hydroxylase) CLIA Kit - 2
  • Human DβH (Dopamine-β-Hydroxylase) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 0.19 ng/mL
Detection Range 0.31-20 ng/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human DβH in samples.No significant cross-reactivity or interference between Human DβH and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
20 33607.000 35641.000 34624.000 34599
10 12865.000 13733.000 13299.000 13274
5 5703.000 5315.000 5509.000 5484
2.5 2622.000 2802.000 2712.000 2687
1.25 1582.000 1432.000 1507.000 1482
0.63 933.000 825.000 879.000 854
0.31 626.000 698.000 662.000 637
0 24.000 26.000 25.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 0.920 2.220 6.940 0.860 2.430 7.090
Standard deviation 0.120 0.180 0.800 0.110 0.230 0.480
CV(%) 13.040 8.110 11.530 12.790 9.470 6.770
Recovery
The recovery of Human DβH was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 93-107 101
EDTA plasma (n=8) 99-111 105
Cell culture media (n=8) 90-106 97
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human DβH and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 102-117 95-111 87-99
Average 109 101 92
1:4 Range 94-106 99-113 98-117
Average 100 107 106
1:8 Range 88-100 87-100 88-101
Average 94 93 93
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human DβH. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human DβH and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human DβH, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human DβH. You can calculate the concentration of Human DβH in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 1621
Uniport ID P09172
Research Area Cancer , Metabolism , Neuroscience
Human DβH (Dopamine-β-Hydroxylase) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定