Human DDC (Dopamine Decarboxylase) CLIA Kit (E-CL-H0798)

Human DDC (Dopamine Decarboxylase) CLIA Kit - 1
  • Human DDC (Dopamine Decarboxylase) CLIA Kit - 1
  • Human DDC (Dopamine Decarboxylase) CLIA Kit - 2
  • Human DDC (Dopamine Decarboxylase) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 18.75 pg/mL
Detection Range 31.25-2000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human DDC in samples.No significant cross-reactivity or interference between Human DDC and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2000 55592.000 57778.000 56685.000 56655
1000 24823.000 26947.000 25885.000 25855
500 12373.000 11289.000 11831.000 11801
250 5456.000 5736.000 5596.000 5566
125 2934.000 2566.000 2750.000 2720
62.5 1451.000 1403.000 1427.000 1397
31.25 677.000 689.000 683.000 653
0 29.000 31.000 30.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 100.820 236.580 706.220 97.540 220.620 756.440
Standard deviation 12.890 17.460 54.100 8.550 20.940 47.660
CV(%) 12.790 7.380 7.660 8.770 9.490 6.300
Recovery
The recovery of Human DDC was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 92-109 99
EDTA plasma (n=8) 101-116 108
Cell culture media (n=8) 99-114 104
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human DDC and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 84-98 99-111 94-109
Average 90 105 99
1:4 Range 88-101 99-117 89-104
Average 94 107 96
1:8 Range 89-102 89-105 83-95
Average 94 96 90
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human DDC. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human DDC and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human DDC, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human DDC. You can calculate the concentration of Human DDC in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 1644
Uniport ID P20711
Research Area Cancer , Metabolism , Neuroscience
Human DDC (Dopamine Decarboxylase) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}