Human GSTpi (Glutathione S Transferases Pi) CLIA Kit (E-CL-H0879)

Human GSTpi (Glutathione S Transferases Pi) CLIA Kit - 1
  • Human GSTpi (Glutathione S Transferases Pi) CLIA Kit - 1
  • Human GSTpi (Glutathione S Transferases Pi) CLIA Kit - 2
  • Human GSTpi (Glutathione S Transferases Pi) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 0.28 ng/mL
Detection Range 0.47-30 ng/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human GSTpi in samples.No significant cross-reactivity or interference between Human GSTpi and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
30 33363.000 37867.000 35615.000 35585
15 14010.000 15380.000 14695.000 14665
7.5 6607.000 5645.000 6126.000 6096
3.75 2738.000 3184.000 2961.000 2931
1.88 1553.000 1505.000 1529.000 1499
0.94 1015.000 879.000 947.000 917
0.47 652.000 686.000 669.000 639
0 30.000 30.000 30.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 1.620 3.830 12.770 1.500 4.000 12.010
Standard deviation 0.180 0.440 1.360 0.180 0.400 1.290
CV(%) 11.110 11.490 10.650 12.000 10.000 10.740
Recovery
The recovery of Human GSTpi was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 87-103 95
EDTA plasma (n=8) 100-111 105
Cell culture media (n=8) 100-115 106
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human GSTpi and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 94-110 101-117 87-98
Average 101 107 93
1:4 Range 85-100 94-106 96-110
Average 91 101 103
1:8 Range 98-115 85-99 83-95
Average 105 92 90
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human GSTpi. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human GSTpi and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human GSTpi, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human GSTpi. You can calculate the concentration of Human GSTpi in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 2950
Uniport ID P09211
Research Area Cancer , Cardiovascular , Metabolism , Neuroscience
Human GSTpi (Glutathione S Transferases Pi) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定