Human HIF-1α (Hypoxia Inducible Factor 1 Alpha) CLIA Kit (E-CL-H0832)

Human HIF-1α (Hypoxia Inducible Factor 1 Alpha) CLIA Kit - 1
  • Human HIF-1α (Hypoxia Inducible Factor 1 Alpha) CLIA Kit - 1
  • Human HIF-1α (Hypoxia Inducible Factor 1 Alpha) CLIA Kit - 2
  • Human HIF-1α (Hypoxia Inducible Factor 1 Alpha) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 18.75 pg/mL
Detection Range 31.25-2000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human HIF-1α in samples.No significant cross-reactivity or interference between Human HIF-1α and analogues was observed
Recovery 80%-120%
Sample Type Tissue homogenates, cell lysates and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2000 52303.000 62637.000 57470.000 57444
1000 23738.000 25490.000 24614.000 24588
500 11859.000 10397.000 11128.000 11102
250 5806.000 5840.000 5823.000 5797
125 2824.000 2730.000 2777.000 2751
62.5 1478.000 1372.000 1425.000 1399
31.25 700.000 732.000 716.000 690
0 25.000 27.000 26.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 107.080 299.650 789.010 97.830 321.720 833.580
Standard deviation 10.630 32.510 49.310 9.710 22.550 65.270
CV(%) 9.930 10.850 6.250 9.930 7.010 7.830
Recovery
The recovery of Human HIF-1α was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 93-107 100
EDTA plasma (n=8) 87-101 94
Cell culture media (n=8) 85-96 91
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human HIF-1α and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 102-118 91-103 102-119
Average 110 97 110
1:4 Range 86-97 90-104 85-98
Average 91 96 91
1:8 Range 91-102 84-96 86-100
Average 97 90 91
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human HIF-1α. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human HIF-1α and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human HIF-1α, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human HIF-1α. You can calculate the concentration of Human HIF-1α in the samples by comparing the RLU value of the samples to the standard curve.
Human HIF-1α (Hypoxia Inducible Factor 1 Alpha) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定