Human IL-6 (Interleukin 6) CLIA Kit (E-CL-H0101)

Human IL-6 (Interleukin 6) CLIA Kit - 1
  • Human IL-6 (Interleukin 6) CLIA Kit - 1
  • Human IL-6 (Interleukin 6) CLIA Kit - 2
  • Human IL-6 (Interleukin 6) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 7.5 pg/mL
Detection Range 12.5-800 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human IL-6 in samples.No significant cross-reactivity or interference between Human IL-6 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
800 49116.000 57830.000 53473.000 53448
400 21501.000 26197.000 23849.000 23824
200 11030.000 9380.000 10205.000 10180
100 4681.000 5197.000 4939.000 4914
50 2551.000 2193.000 2372.000 2347
25 1136.000 1070.000 1103.000 1078
12.5 517.000 593.000 555.000 530
0 25.000 25.000 25.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 37.640 91.690 379.680 36.940 88.530 350.220
Standard deviation 3.590 10.670 31.020 3.800 6.590 34.150
CV(%) 9.540 11.640 8.170 10.290 7.440 9.750
Recovery
The recovery of Human IL-6 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 88-101 95
EDTA plasma (n=8) 94-111 102
Cell culture media (n=8) 98-114 105
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human IL-6 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 98-113 93-104 88-103
Average 105 99 95
1:4 Range 96-109 101-118 104-120
Average 104 109 110
1:8 Range 102-114 103-117 101-115
Average 107 110 108
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human IL-6. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human IL-6 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human IL-6, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human IL-6. You can calculate the concentration of Human IL-6 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 3569
Uniport ID P05231
Research Area Cancer , Metabolism , Immunology , Neuroscience
Human IL-6 (Interleukin 6) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定