Human PDE4D (Phosphodiesterase 4D, cAMP Specific) CLIA Kit (E-CL-H1432)

Human PDE4D (Phosphodiesterase 4D, cAMP Specific) CLIA Kit - 1
  • Human PDE4D (Phosphodiesterase 4D, cAMP Specific) CLIA Kit - 1
  • Human PDE4D (Phosphodiesterase 4D, cAMP Specific) CLIA Kit - 2
  • Human PDE4D (Phosphodiesterase 4D, cAMP Specific) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 37.5 pg/mL
Detection Range 62.5-4000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human PDE4D in samples.No significant cross-reactivity or interference between Human PDE4D and analogues was observed
Recovery 80%-120%
Sample Type Tissue homogenates, cell lysates and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
4000 61894.000 66360.000 64127.000 64092
2000 28367.000 28625.000 28496.000 28461
1000 13512.000 13490.000 13501.000 13466
500 6826.000 7000.000 6913.000 6878
250 3648.000 3346.000 3497.000 3462
125 1726.000 1648.000 1687.000 1652
62.5 774.000 776.000 775.000 740
0 33.000 37.000 35.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 198.980 541.460 1580.650 182.000 569.310 1717.960
Standard deviation 16.060 44.130 139.730 20.490 56.360 165.610
CV(%) 8.070 8.150 8.840 11.260 9.900 9.640
Recovery
The recovery of Human PDE4D was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 86-101 93
EDTA plasma (n=8) 97-110 103
Cell culture media (n=8) 98-115 106
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human PDE4D and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 96-108 92-106 93-110
Average 103 98 101
1:4 Range 85-99 85-99 97-111
Average 91 92 104
1:8 Range 102-115 95-109 99-113
Average 109 101 107
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human PDE4D. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human PDE4D and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human PDE4D, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human PDE4D. You can calculate the concentration of Human PDE4D in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 5144
Uniport ID Q08499
Research Area Cancer , Signaltransduction
Human PDE4D (Phosphodiesterase 4D, cAMP Specific) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定