Human RNASE3/ECP (Ribonuclease A3/Eosinophil Cationic Protein) CLIA Kit (E-CL-H0898)

Human RNASE3/ECP (Ribonuclease A3/Eosinophil Cationic Protein) CLIA Kit - 1
  • Human RNASE3/ECP (Ribonuclease A3/Eosinophil Cationic Protein) CLIA Kit - 1
  • Human RNASE3/ECP (Ribonuclease A3/Eosinophil Cationic Protein) CLIA Kit - 2
  • Human RNASE3/ECP (Ribonuclease A3/Eosinophil Cationic Protein) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 7.5 pg/mL
Detection Range 12.5-800 pg/mL
Sample Volume 100 μL
Total Assay Time 4 h 30 min
Reactivity Human
Specificity This kit recognizes Human RNASE3/ECP in samples.No significant cross-reactivity or interference between Human RNASE3/ECP and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
800 51941.000 58083.000 55012.000 54982
400 21880.000 24642.000 23261.000 23231
200 11487.000 9823.000 10655.000 10625
100 4691.000 4813.000 4752.000 4722
50 2313.000 2231.000 2272.000 2242
25 1226.000 1056.000 1141.000 1111
12.5 517.000 523.000 520.000 490
0 29.000 31.000 30.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 42.420 78.120 275.700 41.660 84.510 257.790
Standard deviation 5.430 5.910 19.440 4.400 6.480 17.920
CV(%) 12.800 7.570 7.050 10.560 7.670 6.950
Recovery
The recovery of Human RNASE3 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 86-99 93
EDTA plasma (n=8) 92-104 98
Cell culture media (n=8) 100-114 108
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human RNASE3 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 89-99 89-103 95-109
Average 94 96 101
1:4 Range 95-111 101-120 88-98
Average 102 109 93
1:8 Range 94-110 102-118 95-111
Average 100 109 101
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human RNASE3/ECP. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human RNASE3/ECP and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human RNASE3/ECP, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human RNASE3/ECP. You can calculate the concentration of Human RNASE3/ECP in the samples by comparing the RLU value of the samples to the standard curve.
Human RNASE3/ECP (Ribonuclease A3/Eosinophil Cationic Protein) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定