Human TBP2 (Thioredoxin Binding Protein 2) CLIA Kit (E-CL-H1086)

Human TBP2 (Thioredoxin Binding Protein 2) CLIA Kit - 1
  • Human TBP2 (Thioredoxin Binding Protein 2) CLIA Kit - 1
  • Human TBP2 (Thioredoxin Binding Protein 2) CLIA Kit - 2
  • Human TBP2 (Thioredoxin Binding Protein 2) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 18.75 pg/mL
Detection Range 31.25-2000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human TBP2 in samples.No significant cross-reactivity or interference between Human TBP2 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2000 55347.000 66085.000 60716.000 60694
1000 23927.000 26707.000 25317.000 25295
500 11957.000 11185.000 11571.000 11549
250 5429.000 5947.000 5688.000 5666
125 2839.000 2611.000 2725.000 2703
62.5 1405.000 1249.000 1327.000 1305
31.25 676.000 762.000 719.000 697
0 21.000 23.000 22.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 95.350 305.250 669.270 94.140 280.700 672.070
Standard deviation 8.990 25.820 65.920 11.000 25.820 57.660
CV(%) 9.430 8.460 9.850 11.680 9.200 8.580
Recovery
The recovery of Human TBP2 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 87-99 93
EDTA plasma (n=8) 94-104 99
Cell culture media (n=8) 92-106 97
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human TBP2 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 87-99 86-99 101-114
Average 92 93 107
1:4 Range 102-118 94-109 98-111
Average 109 101 105
1:8 Range 86-98 90-103 95-110
Average 93 97 103
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human TBP2. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human TBP2 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human TBP2, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human TBP2. You can calculate the concentration of Human TBP2 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 10628
Uniport ID Q9H3M7
Research Area Cancer , Metabolism
Human TBP2 (Thioredoxin Binding Protein 2) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定