Human TLR4 (Toll-Like Receptor 4) CLIA Kit (E-CL-H0986)

Human TLR4 (Toll-Like Receptor 4) CLIA Kit - 1
  • Human TLR4 (Toll-Like Receptor 4) CLIA Kit - 1
  • Human TLR4 (Toll-Like Receptor 4) CLIA Kit - 2
  • Human TLR4 (Toll-Like Receptor 4) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 37.5 pg/mL
Detection Range 62.5-4000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human TLR4 in samples.No significant cross-reactivity or interference between Human TLR4 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
4000 54491.000 65009.000 59750.000 59722
2000 27613.000 33237.000 30425.000 30397
1000 15136.000 13288.000 14212.000 14184
500 6331.000 7079.000 6705.000 6677
250 3708.000 3214.000 3461.000 3433
125 1795.000 1545.000 1670.000 1642
62.5 782.000 844.000 813.000 785
0 28.000 28.000 28.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 193.730 335.070 1584.160 207.300 367.470 1733.160
Standard deviation 20.790 30.790 127.520 21.250 40.160 191.860
CV(%) 10.730 9.190 8.050 10.250 10.930 11.070
Recovery
The recovery of Human TLR4 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 85-97 91
EDTA plasma (n=8) 101-116 107
Cell culture media (n=8) 99-112 105
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human TLR4 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 93-109 93-107 98-115
Average 99 99 105
1:4 Range 88-102 96-109 91-101
Average 94 104 96
1:8 Range 98-112 98-115 88-102
Average 106 105 94
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human TLR4. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human TLR4 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human TLR4, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human TLR4. You can calculate the concentration of Human TLR4 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 7099
Uniport ID O00206
Research Area Cancer , Cardiovascular , Immunology , Microbiology
Human TLR4 (Toll-Like Receptor 4) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定