Human TrxR1 (Thioredoxin Reductase 1) CLIA Kit (E-CL-H1085)

Human TrxR1 (Thioredoxin Reductase 1) CLIA Kit - 1
  • Human TrxR1 (Thioredoxin Reductase 1) CLIA Kit - 1
  • Human TrxR1 (Thioredoxin Reductase 1) CLIA Kit - 2
  • Human TrxR1 (Thioredoxin Reductase 1) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 18.75 pg/mL
Detection Range 31.25-2000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human TrxR1 in samples.No significant cross-reactivity or interference between Human TrxR1 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2000 58335.000 61767.000 60051.000 60014
1000 24850.000 26240.000 25545.000 25508
500 12511.000 10457.000 11484.000 11447
250 5215.000 5841.000 5528.000 5491
125 2783.000 2655.000 2719.000 2682
62.5 1421.000 1271.000 1346.000 1309
31.25 676.000 712.000 694.000 657
0 36.000 38.000 37.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 94.970 300.950 929.280 99.800 279.570 841.330
Standard deviation 11.900 35.780 77.320 9.010 21.470 85.560
CV(%) 12.530 11.890 8.320 9.030 7.680 10.170
Recovery
The recovery of Human TrxR1 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 88-104 96
EDTA plasma (n=8) 89-102 96
Cell culture media (n=8) 93-106 100
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human TrxR1 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 88-99 87-100 92-108
Average 93 92 99
1:4 Range 96-113 98-114 87-100
Average 104 106 94
1:8 Range 96-111 94-107 95-111
Average 104 101 102
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human TrxR1. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human TrxR1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human TrxR1, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Human TrxR1. You can calculate the concentration of Human TrxR1 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 7296
Uniport ID Q16881
Research Area Cancer , CellBiology , Metabolism , Signaltransduction
Human TrxR1 (Thioredoxin Reductase 1) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定