Mitochondrial Membrane Potential Assay Kit (with JC-1) (E-CK-A301)

All Size Price Qty
100Assays $ 369.00
50Assays $ 216.00
20Assays $ 108.00
Add to cart

For research use only.

Detection Principle The decrease of mitochondrial membrane potential is a marker event in the early stage of apoptosis. It occurs before the appearance of nuclear apoptotic features (chromatin condensation and DNA fragmentation). Once the mitochondrial membrane potential collapses, apoptosis is irreversible. JC-1 is an ideal fluorescent probe widely used to detect mitochondrial membrane potential ?Ψm. In normal cells, the mitochondrial membrane potential is high, JC-1 aggregates in the mitochondrial matrix to form a polymer, which can produce red fluorescence. In the early stage of apoptosis, the mitochondrial membrane potential decreases, JC-1 can’t accumulate in the mitochondrial matrix. When JC-1 is a monomer, it can produce green fluorescence. The decrease of cell membrane potential can be detected by the transition of JC-1 from red fluorescence to green fluorescence, and the transition of JC-1 fluorescence color can be used as an early detection indicator of cell apoptosis. The relative ratio of red and green fluorescence is commonly used to measure the ratio of mitochondrial depolarization. The maximum excitation wavelength of JC-1 monomer is 514 nm and the maximum emission wavelength is 529 nm; the maximum excitation wavelength of JC-1 polymer is 585 nm and the maximum emission wavelength is 590 nm.
Detection Method Fluorometric method, Flow cytometry
Sample Type Cell samples
Assay Time 40min
Detection Instrument Flow Cytometer;Fluorescence Microscope
Dye Type JC-1
Ex/Em 514/529, 585/590
Channel Set FITC, PE
Other Reagents Required Ultrapure water
Storage This product can be stored at 2~8°C/-20°C for 12 months with shading light. Please refer to the manual for the specific storage condition of the components.
Expiration date 12 months
Shipping Ice bag
Cat.No. Product Name Sizes
E-CK-A211 Annexin V-FITC/PI Apoptosis Kit 200Assays , 100Assays , 50Assays , 20Assays
E-CK-A320 One-step TUNEL In Situ Apoptosis Kit (Green, FITC) 100Assays , 50Assays , 20Assays
E-CK-A362 Enhanced Cell Counting Kit 8 (WST-8/CCK8) 500Tests , 100Tests
Other Clones

{{antibodyDetailsPage.numTotal}} Results

Other Formats

{{formatDetailsPage.numTotal}} Results

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}