Mouse ApoB (Apolipoprotein B) CLIA Kit (E-CL-M0098)

Mouse ApoB (Apolipoprotein B) CLIA Kit - 1
  • Mouse ApoB (Apolipoprotein B) CLIA Kit - 1
  • Mouse ApoB (Apolipoprotein B) CLIA Kit - 2
  • Mouse ApoB (Apolipoprotein B) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 3.75 ng/mL
Detection Range 6.25-400 ng/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Mouse
Specificity This kit recognizes Mouse ApoB in samples.No significant cross-reactivity or interference between Mouse ApoB and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
400 48102.000 52320.000 50211.000 50178
200 18287.000 22231.000 20259.000 20226
100 8792.000 8336.000 8564.000 8531
50 4347.000 4411.000 4379.000 4346
25 2349.000 2179.000 2264.000 2231
12.5 1208.000 1150.000 1179.000 1146
6.25 686.000 696.000 691.000 658
0 32.000 34.000 33.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 20.250 48.760 170.480 22.180 48.930 183.500
Standard deviation 2.090 5.460 17.820 2.550 4.990 14.220
CV(%) 10.320 11.200 10.450 11.500 10.200 7.750
Recovery
The recovery of Mouse ApoB was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 95-107 102
EDTA plasma (n=8) 101-113 107
Cell culture media (n=8) 85-98 91
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Mouse ApoB and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 103-115 100-114 94-111
Average 109 107 102
1:4 Range 103-116 89-104 104-117
Average 109 96 110
1:8 Range 90-105 90-104 93-106
Average 96 96 100
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Mouse ApoB. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse ApoB and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse ApoB, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Mouse ApoB. You can calculate the concentration of Mouse ApoB in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 238055
Uniport ID E9Q414
Research Area Cancer , Cardiovascular , Metabolism , Signal Transduction
Mouse ApoB (Apolipoprotein B) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定