Mouse APOE (Apolipoprotein E) CLIA Kit (E-CL-M0101)

Mouse APOE (Apolipoprotein E) CLIA Kit - 1
  • Mouse APOE (Apolipoprotein E) CLIA Kit - 1
  • Mouse APOE (Apolipoprotein E) CLIA Kit - 2
  • Mouse APOE (Apolipoprotein E) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 0.19 ng/mL
Detection Range 0.31-20 ng/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Mouse
Specificity This kit recognizes Mouse APO-E in samples.No significant cross-reactivity or interference between Mouse APO-E and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
20 31463.000 37075.000 34269.000 34234
10 12845.000 13229.000 13037.000 13002
5 5944.000 5322.000 5633.000 5598
2.5 2724.000 2822.000 2773.000 2738
1.25 1527.000 1399.000 1463.000 1428
0.63 902.000 890.000 896.000 861
0.31 628.000 716.000 672.000 637
0 35.000 35.000 35.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 1.020 3.210 8.720 1.000 3.530 9.370
Standard deviation 0.100 0.370 0.990 0.100 0.410 0.860
CV(%) 9.800 11.530 11.350 10.000 11.610 9.180
Recovery
The recovery of Mouse ApoE was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 98-113 106
EDTA plasma (n=8) 87-98 92
Cell culture media (n=8) 98-111 105
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Mouse ApoE and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 87-101 91-103 97-108
Average 94 97 103
1:4 Range 92-105 97-108 88-101
Average 99 102 94
1:8 Range 101-119 88-102 97-112
Average 109 95 104
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Mouse APO-E. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse APO-E and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse APO-E, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Mouse APO-E. You can calculate the concentration of Mouse APO-E in the samples by comparing the RLU value of the samples to the standard curve.
Mouse APOE (Apolipoprotein E) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定