Mouse MMP-7 (Matrix Metalloproteinase 7) CLIA Kit (E-CL-M0494)

Mouse MMP-7 (Matrix Metalloproteinase 7) CLIA Kit - 1
  • Mouse MMP-7 (Matrix Metalloproteinase 7) CLIA Kit - 1
  • Mouse MMP-7 (Matrix Metalloproteinase 7) CLIA Kit - 2
  • Mouse MMP-7 (Matrix Metalloproteinase 7) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 9.38 pg/mL
Detection Range 15.63-1000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Mouse
Specificity This kit recognizes Mouse MMP-7 in samples.No significant cross-reactivity or interference between Mouse MMP-7 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
1000 54973.000 62417.000 58695.000 58672
500 22765.000 24547.000 23656.000 23633
250 10955.000 10379.000 10667.000 10644
125 5003.000 5355.000 5179.000 5156
62.5 2645.000 2299.000 2472.000 2449
31.25 1391.000 1291.000 1341.000 1318
15.63 731.000 763.000 747.000 724
0 22.000 24.000 23.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 47.020 123.690 416.570 46.550 133.750 427.380
Standard deviation 6.030 8.960 37.820 4.230 11.810 46.030
CV(%) 12.820 7.240 9.080 9.090 8.830 10.770
Recovery
The recovery of Mouse MMP-7 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 88-99 93
EDTA plasma (n=8) 86-99 93
Cell culture media (n=8) 94-110 100
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Mouse MMP-7 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 91-102 97-112 87-100
Average 97 103 94
1:4 Range 92-104 102-115 90-103
Average 98 108 97
1:8 Range 99-112 92-107 101-120
Average 105 98 109
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Mouse MMP-7. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse MMP-7 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse MMP-7, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Mouse MMP-7. You can calculate the concentration of Mouse MMP-7 in the samples by comparing the RLU value of the samples to the standard curve.
Uniport ID Q10738
Research Area Cancer , CellBiology , Cardiovascular , Signaltransduction
Mouse MMP-7 (Matrix Metalloproteinase 7) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定