Rat ApoA1 (Apolipoprotein A1) CLIA Kit (E-CL-R0710)

Rat ApoA1 (Apolipoprotein A1) CLIA Kit - 1
  • Rat ApoA1 (Apolipoprotein A1) CLIA Kit - 1
  • Rat ApoA1 (Apolipoprotein A1) CLIA Kit - 2
  • Rat ApoA1 (Apolipoprotein A1) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 3.75 ng/mL
Detection Range 6.25-400 ng/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Rat
Specificity This kit recognizes Rat ApoA1 in samples.No significant cross-reactivity or interference between Rat ApoA1 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
400 47942.000 55548.000 51745.000 51714
200 19104.000 20692.000 19898.000 19867
100 9328.000 8046.000 8687.000 8656
50 3942.000 4500.000 4221.000 4190
25 2238.000 2172.000 2205.000 2174
12.5 1181.000 1179.000 1180.000 1149
6.25 693.000 769.000 731.000 700
0 30.000 32.000 31.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 21.680 53.680 181.770 22.000 57.040 196.280
Standard deviation 1.780 5.000 12.360 2.570 5.400 16.980
CV(%) 8.210 9.310 6.800 11.680 9.470 8.650
Recovery
The recovery of Rat ApoA1 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 84-98 91
EDTA plasma (n=8) 94-107 99
Cell culture media (n=8) 95-108 100
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Rat ApoA1 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 95-112 91-106 99-115
Average 103 97 105
1:4 Range 85-99 99-115 96-111
Average 91 107 102
1:8 Range 96-108 98-113 96-110
Average 102 106 102
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Rat ApoA1. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat ApoA1 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat ApoA1, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Rat ApoA1. You can calculate the concentration of Rat ApoA1 in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 25081
Uniport ID P04639
Research Area Cancer , Cardiovascular , Metabolism , Neuroscience , Signal Transduction
Rat ApoA1 (Apolipoprotein A1) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定