Rat CA9 (Carbonic Anhydrase Ⅸ) CLIA Kit (E-CL-R0207)

Rat CA9 (Carbonic Anhydrase Ⅸ) CLIA Kit - 1
  • Rat CA9 (Carbonic Anhydrase Ⅸ) CLIA Kit - 1
  • Rat CA9 (Carbonic Anhydrase Ⅸ) CLIA Kit - 2
  • Rat CA9 (Carbonic Anhydrase Ⅸ) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 7.5 pg/mL
Detection Range 12.5-800 pg/mL
Sample Volume 100 μL
Total Assay Time 4 h 30 min
Reactivity Rat
Specificity This kit recognizes Rat CA9 in samples.No significant cross-reactivity or interference between Rat CA9 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
800 53061.000 54963.000 54012.000 53987
400 21311.000 24565.000 22938.000 22913
200 10851.000 9117.000 9984.000 9959
100 4605.000 5091.000 4848.000 4823
50 2376.000 2206.000 2291.000 2266
25 1160.000 1112.000 1136.000 1111
12.5 526.000 582.000 554.000 529
0 25.000 25.000 25.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 41.850 104.240 289.600 38.430 100.850 267.240
Standard deviation 5.230 11.660 22.390 3.730 9.320 25.710
CV(%) 12.500 11.190 7.730 9.710 9.240 9.620
Recovery
The recovery of Rat CA9 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 86-102 93
EDTA plasma (n=8) 92-107 100
Cell culture media (n=8) 94-105 99
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Rat CA9 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 96-110 89-102 99-116
Average 103 96 106
1:4 Range 95-111 103-119 98-115
Average 102 109 105
1:8 Range 94-105 94-107 98-114
Average 99 99 106
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Rat CA9. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat CA9 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat CA9, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Rat CA9. You can calculate the concentration of Rat CA9 in the samples by comparing the RLU value of the samples to the standard curve.
Rat CA9 (Carbonic Anhydrase Ⅸ) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定