Rat cTn-I/TNNI3 (Cardiac Troponin I) CLIA Kit (E-CL-R0721)

Rat cTn-I/TNNI3 (Cardiac Troponin I) CLIA Kit - 1
  • Rat cTn-I/TNNI3 (Cardiac Troponin I) CLIA Kit - 1
  • Rat cTn-I/TNNI3 (Cardiac Troponin I) CLIA Kit - 2
  • Rat cTn-I/TNNI3 (Cardiac Troponin I) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 7.5 pg/mL
Detection Range 12.5-800 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Rat
Specificity This kit recognizes Rat cTn-I/TNNI3 in samples.No significant cross-reactivity or interference between Rat cTn-I/TNNI3 and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
800 55837.000 58455.000 57146.000 57113
400 20055.000 23451.000 21753.000 21720
200 10533.000 9699.000 10116.000 10083
100 4415.000 5035.000 4725.000 4692
50 2510.000 2302.000 2406.000 2373
25 1148.000 1138.000 1143.000 1110
12.5 485.000 539.000 512.000 479
0 32.000 34.000 33.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 43.140 127.670 380.900 42.340 115.950 403.720
Standard deviation 4.310 14.450 34.930 5.400 10.410 45.380
CV(%) 9.990 11.320 9.170 12.750 8.980 11.240
Recovery
The recovery of Rat cTn-I was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 88-103 95
EDTA plasma (n=8) 95-109 103
Cell culture media (n=8) 89-102 96
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Rat cTn-I and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 103-115 85-96 87-102
Average 109 91 94
1:4 Range 98-112 93-105 98-114
Average 105 99 107
1:8 Range 87-98 102-117 87-102
Average 93 108 95
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Rat cTn-I/TNNI3. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat cTn-I/TNNI3 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat cTn-I/TNNI3, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Rat cTn-I/TNNI3. You can calculate the concentration of Rat cTn-I/TNNI3 in the samples by comparing the RLU value of the samples to the standard curve.
Rat cTn-I/TNNI3 (Cardiac Troponin I) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}