Rat TNF-α (Tumor Necrosis Factor Alpha) CLIA Kit (E-CL-R0019)

Rat TNF-α (Tumor Necrosis Factor Alpha) CLIA Kit - 1
  • Rat TNF-α (Tumor Necrosis Factor Alpha) CLIA Kit - 1
  • Rat TNF-α (Tumor Necrosis Factor Alpha) CLIA Kit - 2
  • Rat TNF-α (Tumor Necrosis Factor Alpha) CLIA Kit - 3
All Size Price Qty
96T $ 682.00
- +
48T $ 546.00
- +
24T $ 180.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 9.38 pg/mL
Detection Range 15.63-1000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Rat
Specificity This kit recognizes Rat TNF-α in samples.No significant cross-reactivity or interference between Rat TNF-α and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Chemiluminescence
Assay Type Sandwich-CLIA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃/-20℃
Expiration Date 6 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
1000 51446.000 61672.000 56559.000 56526
500 22670.000 25880.000 24275.000 24242
250 11170.000 10464.000 10817.000 10784
125 4834.000 5384.000 5109.000 5076
62.5 2664.000 2582.000 2623.000 2590
31.25 1402.000 1290.000 1346.000 1313
15.63 714.000 752.000 733.000 700
0 33.000 33.000 33.000 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 53.290 136.930 449.480 49.990 147.840 445.020
Standard deviation 4.730 12.950 37.130 6.230 16.570 29.240
CV(%) 8.880 9.460 8.260 12.460 11.210 6.570
Recovery
The recovery of Rat TNF-α was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 86-101 92
EDTA plasma (n=8) 99-115 105
Cell culture media (n=8) 98-115 105
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Rat TNF-α and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 102-120 100-116 88-101
Average 109 106 94
1:4 Range 91-104 101-113 84-97
Average 98 107 91
1:8 Range 92-107 98-113 85-97
Average 98 105 91
This CLIA kit uses the Sandwich-CLIA principle. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Rat TNF-α. Samples or Standards are added to the micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat TNF-α and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat TNF-α, biotinylated detection antibody and Avidin-HRP conjugate will appear luminescence. The Relative light unit (RLU) value is measured by the Chemiluminescence immunoassay analyzer at 425nm. The RLU value is positively associated with the concentration of Rat TNF-α. You can calculate the concentration of Rat TNF-α in the samples by comparing the RLU value of the samples to the standard curve.
Gene ID 24835
Uniport ID P16599
Research Area Cancer , Cardiovascular , Metabolism , Immunology , Signal Transduction
Rat TNF-α (Tumor Necrosis Factor Alpha) CLIA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定