Facebook
Toll-free:1-888-852-8623

All categories

  • All categories
  • Flow Cytometry Antibodies
  • Immunoassays
  • Antibodies and Reagents
  • Cell Health and Metabolism Assay Kits
  • Cell Isolation Products
  • Cell Identification Kits
  • Proteins and Peptides
  • Cell Culture
Please enter the item number/product keyword!
Keyword cannot be empty !
INSERT SYMBOLS:
  • α
  • β
  • γ
  • δ
  • ε
  • ζ
  • η
  • θ
  • κ
  • μ
  • ω
  • σ
  • τ
  • λ
  • ⅩⅢ
  • ⅩⅢ
  • ⅩⅣ
  • ⅩⅤ
  • ⅩⅦ
  • ⅩⅧ
  • UP ↑
DHT(Dihydrotestosterone) ELISA Kit - 1
  • DHT(Dihydrotestosterone) ELISA Kit - 1
  • DHT(Dihydrotestosterone) ELISA Kit - 2
  • DHT(Dihydrotestosterone) ELISA Kit - 3
All Size Price Qty
96T $ 495.00
- +
48T $ 396.00
- +
24T $ 150.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 23.44 pg/mL
Detection Range 39.06-2500 pg/mL
Sample Volume 50 μL
Total Assay Time 2 h 30 min
Reactivity Universal
Specificity This kit recognizes Universal DHT in samples.No significant cross-reactivity or interference between Universal DHT and analogues was observed
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Colorimetric method, ELISA, Competitive
Assay Type Competitive-ELISA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃
Expiration Date 12 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2500 0.204 0.208 0.206 -
1250 0.306 0.324 0.315 -
625 0.535 0.545 0.540 -
312.5 0.820 0.816 0.818 -
156.25 1.229 1.231 1.230 -
78.13 1.577 1.583 1.580 -
39.06 1.851 1.927 1.889 -
0 2.345 2.373 2.359 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 128.010 215.480 843.760 123.350 230.340 860.810
Standard deviation 6.200 9.980 54.000 9.790 16.910 69.550
CV(%) 4.840 4.630 6.400 7.940 7.340 8.080
Recovery
The recovery of Universal DHT was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 90-101 96
EDTA plasma (n=8) 90-105 96
Cell culture media (n=8) 89-101 95
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Universal DHT and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 91-103 96-111 88-99
Average 98 102 94
1:4 Range 93-105 97-112 88-100
Average 100 104 95
1:8 Range 90-104 98-110 90-103
Average 95 104 96
Stability
Each kit batch is subjected to accelerated stability testing and real-time stability monitoring. Sample performance is evaluated after storage at 37 °C for 10 days to assess the impact of elevated temperature on assay reliability and reagent integrity.
/ Variation range of 37°C mean
concentration / 2-8°C mean
Sample 1(n=16) 85.02-106.15
Sample 2(n=16) 107.65-112.3
This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with Universal DHT. During the reaction, Universal DHT in the sample or standard competes with a fixed amount of Universal DHT on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Universal DHT. Excess conjugate and unbound sample or standard are washed away, and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns from blue to yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of Universal DHT in tested samples can be calculated by comparing the OD of the samples to the standard curve.
Dihydrotestosterone (DHT) is a hormone that is converted from testosterone in the body. It is the process of converting testosterone into DHT through the action of 5α-reductase. This transformation occurs mainly in the skin and liver. DHT acts similarly to testosterone in the body, but it has a higher affinity in certain tissues, especially in the hair follicles of the prostate and scalp
Research Area Signal Transduction , Developmental Biology
DHT(Dihydrotestosterone) ELISA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

Species

{{relatedElisaPage.numTotal}} Results

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定