Assay type | Sandwich-ELISA |
Format | 96T/48T |
Assay time | 3.5h |
Detection range | 1.56-100 mIU/mL |
Sensitivity | 0.94 mIU/mL |
Sample type &Sample volume | serum, plasma and other biological fluids; 100μL |
Specificity | This kit recognizes Human FSH in samples. No significant cross-reactivity or interference between Human FSH and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are < 10%. |
Application | This ELISA kit applies to the in vitro quantitative determination of Human FSH concentrations in serum, plasma and other biological fluids. |
Item | Specifications | Storage |
---|---|---|
Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips
48T: 8 wells ×6 strips |
-20℃, 6 months |
Reference Standard | 96T: 2 vials
48T: 1 vial |
|
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
|
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
-20℃(Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent | 1 vial, 10 mL | 2-8℃(Protect from light) |
Stop Solution | 1 vial, 10 mL | 2-8°C |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Human FSH were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Human FSH were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (mIU/mL) | 4.90 | 12.20 | 42.60 | 4.90 | 11.10 | 46.20 |
Standard deviation | 0.30 | 0.60 | 1.60 | 0.30 | 0.60 | 1.50 |
CV (%) | 6.12 | 4.92 | 3.76 | 6.12 | 5.41 | 3.25 |
The recovery of Human FSH spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
---|---|---|
Serum(n=8) | 85-96 | 91 |
EDTA plasma (n=8) | 90-101 | 95 |
Cell culture media (n=8) | 92-103 | 97 |
Samples were spiked with high concentrations of Human FSH and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Database Links | SwissProt:
P01225
|
Research Area | Cancer, Metabolism, Signal transduction |
![]() |
1. Add 100μL standard or sample to the wells. Incubate for 90 min at 37°C |
![]() |
2. Discard the liquid, immediately add 100μL Biotinylated Detection Ab working solution to each well. Incubate for 60 min at 37°C |
![]() |
3. Aspirate and wash the plate for 3 times |
![]() |
4. Add 100μL HRP conjugate working solution. Incubate for 30 min at 37°C. Aspirate and wash the plate for 5 times |
![]() |
5. Add 90μL Substrate Reagent. Incubate for 15 min at 37°C |
![]() |
6. Add 50μL Stop Solution |
![]() |
7. Read the plate at 450nm immediately. Calculation of the results |
From now on, if you have published a paper by using any of our products since 1/1/2019, fill out the “Elabscience Publication Reward Application Form”carefully and send it to orders@elabscience.com, we will get back to you with the reward after we confirm it ASAP!
Sample: human gonadotrophic pituitary adenoma stem cells ( |
PMID: 35626727 |
Sample: serum |
Sample: Serum |
PMID: 33484907 |
Sample: Serum |
PMID: 30641075 |
Sample: Serum,Cell culture medium |
DOI: 10.1530/REP-20-0643 |
|
PMID: 33989172 |
Sample: serum |
DOI: 10.1111/and.14621 |
|
PMID: 36261884 |
Sample: serum |
A***********SSubmitted [ Mar 11 2023 ]
Asked: Can this kit be used to test salivary FSH? And what considerations should be taken (should saliva be centrifuged first? Saliva storage before using it on this kit?)
Reply
adminSubmitted [ Mar 11 2023 ]
Answered: Hi Abdulrahman, We have verified human saliva samples with E-EL-H1143, and the detection value are very low, and most of the OD values are no signal. It is not recommended to use this kit to detect saliva samples. Here are the recommendations for collection and preservation of saliva samples: Patients should fast and gargle one hour before sampling to keep the mouth clean. Saliva samples should be centrifuged at 2-8℃, 12000r/min for 10 minutes to remove impurities, and take the supernatant for detection. It is recommended to use fresh saliva samples for testing. Samples could be stored for one month at - 20 ℃ and three months at - 80 ℃. If any further questions, pls email to customer00@elabscience.com Best regards