Facebook
Toll-free:1-888-852-8623

All categories

  • All categories
  • Flow Cytometry Antibodies
  • Immunoassays
  • Antibodies and Reagents
  • Cell Health and Metabolism Assay Kits
  • Cell Isolation Products
  • Cell Identification Kits
  • Proteins and Peptides
  • Cell Culture
Please enter the item number/product keyword!
Keyword cannot be empty !
INSERT SYMBOLS:
  • α
  • β
  • γ
  • δ
  • ε
  • ζ
  • η
  • θ
  • κ
  • μ
  • ω
  • σ
  • τ
  • λ
  • ⅩⅢ
  • ⅩⅢ
  • ⅩⅣ
  • ⅩⅤ
  • ⅩⅦ
  • ⅩⅧ
  • UP ↑
Micro-Sample

Mini Sample Human IgE (Immunoglobulin E) ELISA Kit (E-MSEL-H0008)

Mini Sample Human IgE (Immunoglobulin E) ELISA Kit - 1
  • Mini Sample Human IgE (Immunoglobulin E) ELISA Kit - 1
  • Mini Sample Human IgE (Immunoglobulin E) ELISA Kit - 2
  • Mini Sample Human IgE (Immunoglobulin E) ELISA Kit - 3
All Size Price Qty
96T $ 510.00
- +
48T $ 408.00
- +
24T $ 150.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary

The sample size of MS series ELISA kit is only 1/4 of that of the traditional sandwich ELISA kit, which can effectively solve the problem of insufficient sample size.

Sensitivity 0.19 ng/mL
Detection Range 0.31-20 ng/mL
Sample Volume 25 μL
Manual Operation Time 1 h
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes IgE in samples.No significant cross-reactivity or interference between IgE and analogues was observed.
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Colorimetric method, ELISA, Sandwich
Assay Type Sandwich-ELISA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃
Expiration Date 12 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
20 2.472 2.426 2.449 2.364
10 1.644 1.688 1.666 1.581
5 1.032 1.068 1.050 0.965
2.5 0.611 0.597 0.604 0.519
1.25 0.329 0.327 0.328 0.243
0.63 0.193 0.205 0.199 0.114
0.31 0.134 0.135 0.135 0.050
0 0.083 0.087 0.085 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 0.920 2.780 7.870 0.940 2.840 7.690
Standard deviation 0.040 0.150 0.330 0.070 0.200 0.690
CV(%) 4.090 5.230 4.170 7.290 6.920 8.970
Recovery
The recovery of Human IgE was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 93-103 98
EDTA plasma (n=8) 87-103 94
Cell culture media (n=8) 85-98 90
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human IgE and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 83-95 90-103 86-100
Average 90 98 92
1:4 Range 80-94 94-108 83-93
Average 87 99 88
1:8 Range 81-93 92-107 84-95
Average 86 99 90
Stability
Each kit batch is subjected to accelerated stability testing and real-time stability monitoring. Sample performance is evaluated after storage at 37 °C for 10 days to assess the impact of elevated temperature on assay reliability and reagent integrity.
/ Variation range of 37°C mean
concentration / 2-8°C mean
Sample 1(n=16) 95.01-100.07
Sample 2(n=16) 86.91-106.72
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to IgE . Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for IgE and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain IgE , biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of IgE . You can calculate the concentration of IgE in the samples by comparing the OD of the samples to the standard curve.
IgE, Immunoglobulin E (Ige), is a kind of immune globulin, mainly involved in allergic reactions and parasitic infections and other immune reactions. IgE can produce allergic reactions, such as asthma and allergic rhinitis, when the body is exposed to certain antigens. Measurement of IgE levels can help diagnose and monitor the extent of these allergic reactions and the efficacy of treatment.
Gene Alias IGHE
Gene ID 3497
Uniport ID P01854
Protein Alias IGHE
Research Area Immunology
Mini Sample Human IgE (Immunoglobulin E) ELISA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

Species

{{relatedElisaPage.numTotal}} Results

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定