Facebook
Toll-free:1-888-852-8623

All categories

  • All categories
  • Flow Cytometry Antibodies
  • Immunoassays
  • Antibodies and Reagents
  • Cell Health and Metabolism Assay Kits
  • Cell Isolation Products
  • Cell Identification Kits
  • Proteins and Peptides
  • Cell Culture
Please enter the item number/product keyword!
Keyword cannot be empty !
INSERT SYMBOLS:
  • α
  • β
  • γ
  • δ
  • ε
  • ζ
  • η
  • θ
  • κ
  • μ
  • ω
  • σ
  • τ
  • λ
  • ⅩⅢ
  • ⅩⅢ
  • ⅩⅣ
  • ⅩⅤ
  • ⅩⅦ
  • ⅩⅧ
  • UP ↑
Micro-Sample

Mini Sample Human IL-8 (Interleukin 8) ELISA Kit (E-MSEL-H0043)

Mini Sample Human IL-8 (Interleukin 8) ELISA Kit - 1
  • Mini Sample Human IL-8 (Interleukin 8) ELISA Kit - 1
  • Mini Sample Human IL-8 (Interleukin 8) ELISA Kit - 2
  • Mini Sample Human IL-8 (Interleukin 8) ELISA Kit - 3
All Size Price Qty
96T $ 510.00
- +
48T $ 408.00
- +
24T $ 150.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary

The sample size of MS series ELISA kit is only 1/4 of that of the traditional sandwich ELISA kit, which can effectively solve the problem of insufficient sample size.

Sensitivity 18.75 pg/mL
Detection Range 31.25-2000 pg/mL
Sample Volume 25 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes Human IL-8 in samples. No significant cross-reactivity or interference between Human IL-8 and analogues was observed.
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Colorimetric method, ELISA, Sandwich
Assay Type Sandwich-ELISA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃
Expiration Date 12 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
2000 2.503 2.395 2.449 2.367
1000 1.763 1.769 1.766 1.684
500 1.011 1.017 1.014 0.932
250 0.591 0.573 0.582 0.500
125 0.302 0.304 0.303 0.221
62.5 0.193 0.185 0.189 0.107
31.25 0.135 0.145 0.140 0.058
0 0.080 0.084 0.082 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human IL-6 were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 94.070 306.740 825.060 88.240 327.610 839.950
Standard deviation 5.310 17.640 50.580 7.310 20.280 56.700
CV(%) 5.650 5.750 6.130 8.280 6.190 6.750
Recovery
The recovery of Human IL-8 was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 96-108 101
EDTA plasma (n=8) 88-104 95
Cell culture media (n=8) 92-106 97
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human IL-8 and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 87-101 98-112 94-109
Average 93 106 101
1:4 Range 84-98 95-110 94-107
Average 90 102 100
1:8 Range 83-97 98-114 91-108
Average 89 104 98
Stability
Each kit batch is subjected to accelerated stability testing and real-time stability monitoring. Sample performance is evaluated after storage at 37 °C for 10 days to assess the impact of elevated temperature on assay reliability and reagent integrity.
/ Variation range of 37°C mean
concentration / 2-8°C mean
Sample 1(n=16) 101.60-109.54
Sample 2(n=16) 85.48-110.40
Interleukin-8 (IL-8) is a chemokine produced by macrophages and other cell types such as epithelial cells, airway smooth muscle cells, and endothelial cells.In humans, it is encoded by the IL-8 gene.IL-8 can effectively promote angiogenesis and play an important role in the pathogenesis of bronchiolitis. IL-8 can be induced by the recruitment and degranulation of neutrophils.It can act as an autocrine growth factor in colon cancer cell lines by regulating the inflammatory response. High levels of IL-8 reduce schizophrenia.Positive reaction to antipsychotic drugs in patients with schizophrenia. In addition, IL-8 has been implicated in the pathogenesis of obesity and cystic fibrosi.
Gene Alias CXCL8
Gene ID 3576
Uniport ID P10145
Protein Alias CXCL8
Research Area Immunology
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

Species

{{relatedElisaPage.numTotal}} Results

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定