Assay type | Sandwich-ELISA |
Format | 96T/48T/24 |
Assay time | 3.5h |
Detection range | 0.31-20 ng/mL |
Sensitivity | 0.19 ng/mL |
Sample type &Sample volume | serum, plasma and other biological fluids; 100μL |
Specificity | This kit recognizes Mouse LH in samples. No significant cross-reactivity or interference between Mouse LH and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are < 10%. |
Application | This ELISA kit applies to the in vitro quantitative determination of Mouse LH concentrations in serum, plasma and other biological fluids. |
Item | Specifications | Storage |
---|---|---|
Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips
48T: 8 wells ×6 strips |
-20℃, 12 months |
Reference Standard | 96T: 2 vials
48T: 1 vial |
|
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
|
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
-20℃(Protect from light), 12 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 12 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent | 1 vial, 10 mL | 2-8℃(Protect from light) |
Stop Solution | 1 vial, 10 mL | 2-8°C |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Mouse LH were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Mouse LH were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (ng/mL) | 0.81 | 2.24 | 8.84 | 0.89 | 2.37 | 8.19 |
Standard deviation | 0.04 | 0.11 | 0.41 | 0.05 | 0.12 | 0.38 |
CV (%) | 4.94 | 4.91 | 4.64 | 5.62 | 5.06 | 4.64 |
The recovery of Mouse LH spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
---|---|---|
Serum(n=8) | 95-105 | 101 |
EDTA plasma (n=8) | 88-100 | 93 |
Cell culture media (n=8) | 88-96 | 93 |
Samples were spiked with high concentrations of Mouse LH and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Synonyms | Lutropin, Lutrophin |
Research Area | Neuroscience, Signal transduction |
1. Add 100μL standard or sample to the wells. Incubate for 90 min at 37°C |
|
2. Discard the liquid, immediately add 100μL Biotinylated Detection Ab working solution to each well. Incubate for 60 min at 37°C |
|
3. Aspirate and wash the plate for 3 times |
|
4. Add 100μL HRP conjugate working solution. Incubate for 30 min at 37°C. Aspirate and wash the plate for 5 times |
|
5. Add 90μL Substrate Reagent. Incubate for 15 min at 37°C |
|
6. Add 50μL Stop Solution |
|
7. Read the plate at 450nm immediately. Calculation of the results |
Sample: Serum |
Sample: Serum |
Sample: Serum |
Sample: Serum,Tissue Homogenate |
DOI: 10.1071/RD20112 |
|
PMID: 32998795 |
Sample: Blood |
PMID: 31469002 |
Sample: Plasma |
DOI: 10.1071/RD22108 |
|
PMID: 36219878 |
Sample: Serum |
PMID: 35344846 |
Sample: Serum |
DOI: 10.1002/mrd.23404 |
|
Sample: Serum |
DOI: 10.1155/2021/9968463 |
|
PMID: 34987599 |
Sample: Serum |
Sample: Serum |
PMID: 33292347 |
Sample: Serum |
PMID: 35870259 |
Sample: Blood |
Sample: Serum |
PMID: 32051875 |
Sample: Serum |
Sample: Serum |
Sample: Serum |
Sample: Plasma |
PMID: 34828406 |
Sample: Plasma |
PMID: 34280466 |
Sample: Serum |
DOI: 10.1038/srep43475 |
|
Sample: Serum |
Sample: Serum |
PMID: 33684516 |
Sample: Serum |
PMID: 35921919 |
Sample: Serum |
DOI: 10.1530/JOE-18-0533 |
|
Sample: Serum |
DOI: 10.1530/JOE-19-0082 |
|
Sample: Serum |
PMID: 35962055 |
Sample: Serum |
Sample: Serum |
PMID: 33581723 |
Sample: Serum |
DOI: 10.1039/D1FO04239D |
|
PMID: 35083997 |
Sample: Serum |
Sample: Serum |
DOI: 10.2147/IJN.S348673 |
|
PMID: 35401001 |
Sample: Serum |
PMID: 30768966 |
Sample: Serum |
PMID: 35658231 |
Sample: Serum |
Sample: Serum |
Sample: Serum |
DOI: 10.2337/db20-0436 |
|
Sample: Serum |
PMID: 34167001 |
Sample: Serum |
PMID: 36309297 |
Sample: Testicular Tissues |
PMID: 35177090 |
Sample: Serum |
S***********sSubmitted [ Jul 06 2023 ]
Asked: Has this ELISA been tested using urine?
Reply
adminSubmitted [ Jul 06 2023 ]
Answered: According to our internal tests, the E-EL-M3053 kit can detect urine samples.
S***********sSubmitted [ Jul 06 2023 ]
Asked: Has this ELISA been used to test the LH levels of pregnant mice at different E days?
Reply
adminSubmitted [ Jul 06 2023 ]
Answered: From the citations of E-EL-M3053, the detection report about LH levels of pregnant mice at different E days have not been found at present.