Facebook

All categories

  • All categories
  • Flow Cytometry Antibodies
  • Immunoassays
  • Cell Isolation and Identification
  • Cell Health and Metabolism Assay Kits
  • Cell Culture
  • Antibodies and Reagents
  • Proteins and Peptides
Please enter the item number/product keyword!
Keyword cannot be empty !
INSERT SYMBOLS:
  • α
  • β
  • γ
  • δ
  • ε
  • ζ
  • η
  • θ
  • κ
  • μ
  • ω
  • σ
  • τ
  • λ
  • Ⅰ
  • Ⅱ
  • Ⅲ
  • Ⅳ
  • Ⅴ
  • Ⅵ
  • Ⅶ
  • Ⅷ
  • Ⅸ
  • Ⅹ
  • Ⅺ
  • Ⅻ
  • ⅩⅢ
  • ⅩⅢ
  • ⅩⅣ
  • ⅩⅤ
  • ⅩⅦ
  • ⅩⅧ
  • UP ↑
All Size Price Qty
96T $ 609.00
- +
48T $ 487.00
- +
24T $ 150.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 0.1 ng/mL
Detection Range 0.16-10 ng/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Mouse
Specificity This kit recognizes Mouse SELP in samples. No significant cross-reactivity or interference between Mouse SELP and analogues was observed
Recovery 80%-120%
Sample Type Serum, EDTA plasma, Urine, Tissue homogenate and Cell culture supernatant
Detection Method Colorimetric method, ELISA, Sandwich
Assay Type Sandwich-ELISA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃
Expiration Date 12 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
10 2.276 2.304 2.290 2.218
5 1.544 1.598 1.571 1.499
2.5 0.931 0.919 0.925 0.853
1.25 0.494 0.510 0.502 0.430
0.63 0.310 0.310 0.310 0.238
0.32 0.187 0.181 0.184 0.112
0.16 0.123 0.135 0.129 0.057
0 0.070 0.074 0.072 -
Sample Values
EDTA plasma:This kit has been validated using samples from apparently healthy individuals. The data is for reference only.
Serum:This kit has been validated using samples from apparently healthy individuals. The data is for reference only.
Sample Type Sample Size Range Recommended Dilution Factor
Mouse EDTA plasma 30 ND-51.65 ng/mL 20-200
Mouse Serum 30 72.74-107.14 ng/mL 20-200
Urine:This kit has been validated using samples from apparently healthy individuals. The data is for reference only.
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Mouse SELP were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Mouse SELP were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 0.550 1.170 3.900 0.560 1.170 3.590
Standard deviation 0.030 0.070 0.260 0.050 0.090 0.280
CV(%) 5.250 6.180 6.650 8.260 7.660 7.700
Recovery
The recovery of Mouse SELP was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Cell culture media (n=8) 92-103 98
Serum (n=8) 91-109 99
EDTA plasma (n=8) 90-104 95
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Mouse SELP and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 85-100 98-110 89-103
Average 92 104 95
1:4 Range 98-109 84-97 93-109
Average 104 91 100
1:8 Range 96-111 86-98 97-112
Average 103 91 105
Stability
Each kit batch is subjected to accelerated stability testing and real-time stability monitoring. Sample performance is evaluated after storage at 37 °C for 10 days to assess the impact of elevated temperature on assay reliability and reagent integrity.
/ Variation range of 37°C mean
concentration / 2-8°C mean
Sample 1(n=16) 95.05-112.69
Sample 2(n=16) 87.37-102.73
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Mouse SELP. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse SELP and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse SELP, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Mouse SELP. You can calculate the concentration of Mouse SELP in the samples by comparing the OD of the samples to the standard curve.
P-selectin (SELP), also known as CD62P, is a 140 kDa transmembrane glycoprotein of the selectin family. It is stored preformed in the alpha-granules of platelets and in the Weibel-Palade bodies of endothelial cells and carries an N-terminal C-type lectin domain followed by an epidermal growth factor-like module and complement regulatory repeats. It appears on the cell surface only after activation and degranulation. Upon platelet or endothelial activation, P-selectin rapidly translocates to the plasma membrane, where it binds sialylated Lewis antigens and P-selectin glycoprotein ligand 1 on neutrophils and monocytes in a calcium-dependent manner. This supports leukocyte rolling and adhesion during inflammation and mediates platelet-leukocyte aggregate formation. Its extracellular domain is proteolytically shed into the circulation as a soluble form that serves as a marker of activation. Soluble P-selectin in plasma is elevated in cardiovascular and cerebrovascular disease, venous thrombosis, diabetes and systemic inflammatory conditions, reflecting concurrent platelet and endothelial activation. This ELISA kit enables sensitive quantitative determination of soluble P-selectin in serum, plasma and other body fluids, supporting research on atherosclerosis, acute coronary syndromes and thrombo-inflammatory disorders.
Gene ID 20344
Uniport ID Q01102
Research Area Cancer , Cardiovascular , Immunology , Stemcells
Product Recommendations for Literature Synchronization

Note: Data for this module come from published literature that cites this product, displaying other products used together in the same research paper.

Reactivity

{{relatedElisaPage.numTotal}} Results

Mouse SELP(P-Selectin) ELISA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定