Current Position:Home>>Hot>>QuicKey Pro ELISA>> QuicKey Pro Chicken CORT(Corticosterone) ELISA Kit
Cat.No.:E-OSEL-Ch0002
Welcome to order from local distributors.
Add to cart Bulk requestFor research use only. Order now, ship in 3 days
Get more sensitive and precise results with saving at least 1-2h comparing to traditional ELISA Kits. The new developed technology in house will help to accelerate your science research in a more efficient way.
Assay type | Competitive-ELISA |
Format | 96T/48T/24 |
Assay time | 1.5h |
Detection range | 3.13-200 ng/mL |
Sensitivity | 1.89 ng/mL |
Sample type &Sample volume | serum and plasma; 50μL |
Specificity | This kit recognizes Cort in samples. No significant cross-reactivity or interference between Cort and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are < 10%. |
Application | This ELISA kit applies to the in vitro quantitative determination of Cort concentrations in serum and plasma. |
Item | Specifications | Storage |
---|---|---|
Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips
48T: 8 wells ×6 strips 24T: 8 wells ×3 strips 96T*5: 5 plates, 96T |
2-8℃, 1 months |
Reference Standard | 96T: 2 vials
48T/24T: 1 vial 96T*5: 10 vials |
2-8℃, use the reconstituted standard within 24h |
Concentrated HRP Linked Detection Ab(100×) | 96T: 1 vial, 60 μL
48T/24T: 1 vial, 30 μL 96T*5: 5 vials, 60 μL |
2-8℃(Protect from light) |
Reference Standard & Sample Diluent | 96T/48T/24T: 1 vial, 20 mL 96T*5: 5 vials, 20 mL |
2-8℃ |
HRP Linked Ab Diluent | 96T/48T/24T: 1 vial, 14 mL 96T*5: 5 vials, 14 mL |
|
Concentrated Wash Buffer(25×) | 96T/48T/24T: 1 vial, 30 mL 96T*5: 5 vials, 30 mL |
|
Substrate Reagent | 96T/48T/24T: 1 vial, 10 mL 96T*5: 5 vials, 10 mL |
2-8℃(Protect from light) |
Stop Solution | 96T/48T/24T: 1 vial, 10 mL 96T*5: 5 vials, 10 mL |
2-8℃ |
Plate Sealer | 96T/48T/24T: 5 pieces 96T*5: 25 pieces |
|
Product Description | 1 copy | |
Certificate of Analysis | 1 copy |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Cort were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Cort were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (ng/mL) | 10.37 | 31.21 | 72.60 | 10.56 | 29.42 | 71.81 |
Standard deviation | 0.61 | 1.49 | 2.48 | 0.73 | 1.61 | 2.50 |
CV (%) | 5.84 | 4.77 | 3.41 | 6.95 | 5.46 | 3.48 |
The recovery of Cort spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
---|---|---|
Serum(n=8) | 88-102 | 95 |
EDTA plasma(n=8) | 92-104 | 98 |
Samples were spiked with high concentrations of Chicken Cort and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Synonyms | Corticosterone,CORT |
Research Area | Cell biology |
PMID: 34872591 |
Sample: Plasma |