Current Position:Home>>Hot>>QuicKey Pro ELISA>> QuicKey Pro Human CRP(C-Reactive Protein) ELISA Kit
Cat.No.:E-OSEL-H0002
Welcome to order from local distributors.
Add to cart Bulk requestFor research use only. Order now, ship in 3 days
Get more sensitive and precise results with saving at least 1-2h comparing to traditional ELISA Kits. The new developed technology in house will help to accelerate your science research in a more efficient way.
Assay type | Sandwich-ELISA |
Format | 96T/48T/24 |
Assay time | 1.5h |
Detection range | 125.00-8000 pg/mL |
Sensitivity | 52.10 pg/mL |
Sample type &Sample volume | serum and plasma; 50μL |
Specificity | This kit recognizes CRP in samples. No significant cross-reactivity or interference between CRP and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are < 10%. |
Application | This ELISA kit applies to the in vitro quantitative determination of CRP concentrations in serum and plasma. |
Item | Specifications | Storage |
---|---|---|
Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips
48T: 8 wells ×6 strips 24T: 8 wells ×3 strips 96T*5: 5 plates, 96T |
2-8℃, 1 months |
Reference Standard | 96T: 2 vials
48T/24T: 1 vial 96T*5: 10 vials |
2-8℃, use the reconstituted standard within 24h |
Concentrated HRP Linked Detection Ab(100×) | 96T: 1 vial, 60 μL
48T/24T: 1 vial, 30 μL 96T*5: 5 vials, 60 μL |
2-8℃(Protect from light) |
Reference Standard & Sample Diluent | 96T/48T/24T: 1 vial, 20 mL 96T*5: 5 vials, 20 mL |
2-8℃ |
HRP Linked Ab Diluent | 96T/48T/24T: 1 vial, 14 mL 96T*5: 5 vials, 14 mL |
|
Concentrated Wash Buffer(25×) | 96T/48T/24T: 1 vial, 30 mL 96T*5: 5 vials, 30 mL |
|
Substrate Reagent | 96T/48T/24T: 1 vial, 10 mL 96T*5: 5 vials, 10 mL |
2-8℃(Protect from light) |
Stop Solution | 96T/48T/24T: 1 vial, 10 mL 96T*5: 5 vials, 10 mL |
2-8℃ |
Plate Sealer | 96T/48T/24T: 5 pieces 96T*5: 25 pieces |
|
Product Description | 1 copy | |
Certificate of Analysis | 1 copy |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level CRP were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level CRP were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (pg/mL) | 386.18 | 1002.03 | 2700.34 | 395.70 | 992.83 | 2854.52 |
Standard deviation | 22.59 | 52.91 | 85.87 | 25.25 | 43.39 | 134.73 |
CV (%) | 5.85 | 5.28 | 3.18 | 6.38 | 4.37 | 4.72 |
The recovery of CRP spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
---|---|---|
Serum(n=8) | 85-100 | 91 |
EDTA plasma(n=8) | 91-104 | 98 |
Samples were spiked with high concentrations of Human CRP and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Database Links | SwissProt: P02741 |
Synonyms | C-Reactive Protein,CRP,PTX1 |
Research Area | Cancer, Cardiovascular, Epigenetics and Nuclear Signaling, Metabolism, Immunology |
Sample: Plasma |
DOI: 10.1093/ndt/gfaa335 |
|
Sample: Serum |
DOI: 10.1111/jcpe.13400 |
|
Sample: Serum,Gingival Crevicular Fluid |
Sample: Plasma |
PMID: 31629608 |
Sample: Serum |
Sample: Plasm |
PMID: 33338706 |
Sample: Serum |
Sample: Blood |
PMID: 32924613 |
Sample: Serum |
PMID: 35624413 |
Sample: Serum |
DOI: 10.21037/apm-21-2168 |
|
Sample: Blood |
Sample: Serum |
DOI: 10.1002/iub.1458 |
|
Sample: Cell Culture Supernatant |
PMID: 30582504 |
Sample: Stool |
DOI: 10.1159/000490246 |
|
Sample: Serum |
PMID: 34166896 |
Sample: Plasma |
PMID: 33859244 |
Sample: Plasma |
DOI: 10.3390/nu12092644 |
|
PMID: 32872655 |
Sample: Plasma |
PMID: 35429740 |
Sample: Serum |
PMID: 34720537 |
Sample: Serum |
PMID: 32949690 |
Sample: Tissue Homogenate |
DOI: 10.3390/nu15010194 |
|
Sample: Serum |
PMID: 35934405 |
Sample: Aunbp@Ag |