Current Position:Home>>Hot>>QuicKey Pro ELISA>> QuicKey Pro Human FE(Ferritin) ELISA Kit
Cat.No.:E-OSEL-H0003
Welcome to order from local distributors.
Add to cart Bulk requestFor research use only. Order now, ship in 3 days
Get more sensitive and precise results with saving at least 1-2h comparing to traditional ELISA Kits. The new developed technology in house will help to accelerate your science research in a more efficient way.
Assay type | Sandwich-ELISA |
Format | 96T/48T/24 |
Assay time | 1.5h |
Detection range | 62.50-4000 pg/mL |
Sensitivity | 24.31 pg/mL |
Sample type &Sample volume | serum and plasma; 50μL |
Specificity | This kit recognizes FE in samples. No significant cross-reactivity or interference between FE and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are < 10%. |
Application | This ELISA kit applies to the in vitro quantitative determination of FE concentrations in serum and plasma. |
Item | Specifications | Storage |
---|---|---|
Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips
48T: 8 wells ×6 strips 24T: 8 wells ×3 strips 96T*5: 5 plates, 96T |
2-8℃, 1 months |
Reference Standard | 96T: 2 vials
48T/24T: 1 vial 96T*5: 10 vials |
2-8℃, use the reconstituted standard within 24h |
Concentrated HRP Linked Detection Ab(100×) | 96T: 1 vial, 60 μL
48T/24T: 1 vial, 30 μL 96T*5: 5 vials, 60 μL |
2-8℃(Protect from light) |
Reference Standard & Sample Diluent | 96T/48T/24T: 1 vial, 20 mL 96T*5: 5 vials, 20 mL |
2-8℃ |
HRP Linked Ab Diluent | 96T/48T/24T: 1 vial, 14 mL 96T*5: 5 vials, 14 mL |
|
Concentrated Wash Buffer(25×) | 96T/48T/24T: 1 vial, 30 mL 96T*5: 5 vials, 30 mL |
|
Substrate Reagent | 96T/48T/24T: 1 vial, 10 mL 96T*5: 5 vials, 10 mL |
2-8℃(Protect from light) |
Stop Solution | 96T/48T/24T: 1 vial, 10 mL 96T*5: 5 vials, 10 mL |
2-8℃ |
Plate Sealer | 96T/48T/24T: 5 pieces 96T*5: 25 pieces |
|
Product Description | 1 copy | |
Certificate of Analysis | 1 copy |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level FE were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level FE were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (pg/mL) | 183.00 | 362.63 | 1422.41 | 190.21 | 332.97 | 1312.84 |
Standard deviation | 12.04 | 15.56 | 58.60 | 10.44 | 16.62 | 69.19 |
CV (%) | 6.58 | 4.29 | 4.12 | 5.49 | 4.99 | 5.27 |
The recovery of FE spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
---|---|---|
Serum(n=8) | 87-101 | 92 |
EDTA plasma(n=8) | 90-105 | 97 |
Urine(n=8) | 91-105 | 99 |
Samples were spiked with high concentrations of Human FE and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Database Links | SwissProt: P02792,P02794 |
Synonyms | Ferritin,FE |
Research Area | Cancer, Cardiovascular, Metabolism, Neuroscience, Signal transduction |
Sample: Blood |
Sample: Serum |
PMID: 35333885 |
Sample: Plasma |
Sample: Plasma |
Sample: Serum |
Sample: Serum |
Sample: Serum |
Sample: Plasma |