Assay type | Competitive-ELISA |
Format | 96T/48T/24 |
Assay time | 1.5h |
Detection range | 15.63-1000 pg/mL |
Sensitivity | 7.01 pg/mL |
Sample type &Sample volume | serum and plasma; 50μL |
Specificity | This kit recognizes Pg in samples. No significant cross-reactivity or interference between Pg and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are < 10%. |
Application | This ELISA kit applies to the in vitro quantitative determination of Pg concentrations in serum and plasma. |
Item | Specifications | Storage |
---|---|---|
Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips
48T: 8 wells ×6 strips 24T: 8 wells ×3 strips 96T*5: 5 plates, 96T |
2-8℃, 1 months |
Reference Standard | 96T: 2 vials
48T/24T: 1 vial 96T*5: 10 vials |
2-8℃, use the reconstituted standard within 24h |
Concentrated HRP Linked Detection Ab(100×) | 96T: 1 vial, 60 μL
48T/24T: 1 vial, 30 μL 96T*5: 5 vials, 60 μL |
2-8℃(Protect from light) |
Reference Standard & Sample Diluent | 96T/48T/24T: 1 vial, 20 mL 96T*5: 5 vials, 20 mL |
2-8℃ |
HRP Linked Ab Diluent | 96T/48T/24T: 1 vial, 14 mL 96T*5: 5 vials, 14 mL |
|
Concentrated Wash Buffer(25×) | 96T/48T/24T: 1 vial, 30 mL 96T*5: 5 vials, 30 mL |
|
Substrate Reagent | 96T/48T/24T: 1 vial, 10 mL 96T*5: 5 vials, 10 mL |
2-8℃(Protect from light) |
Stop Solution | 96T/48T/24T: 1 vial, 10 mL 96T*5: 5 vials, 10 mL |
2-8℃ |
Plate Sealer | 96T/48T/24T: 5 pieces 96T*5: 25 pieces |
|
Product Description | 1 copy | |
Certificate of Analysis | 1 copy |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Pg were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Pg were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (pg/mL) | 51.82 | 153.05 | 376.37 | 50.57 | 167.62 | 390.77 |
Standard deviation | 3.26 | 7.61 | 17.39 | 2.91 | 8.55 | 19.58 |
CV (%) | 6.30 | 4.97 | 4.62 | 5.76 | 5.10 | 5.01 |
The recovery of Pg spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
---|---|---|
Serum(n=8) | 91-101 | 96 |
EDTA plasma(n=8) | 94-107 | 101 |
Samples were spiked with high concentrations of Rat Pg and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Synonyms | Progesterone,Pg |
Research Area | Signal Transduction |
Sample: Serum |
Sample: Serum |
Sample: Serum |
DOI: 10.1111/rda.13172 |
|
Sample: Serum |
DOI: 10.1039/C8TX00263K |
|
PMID: 31160972 |
Sample: Cell Culture Medium |
Sample: Serum |
DOI: 10.1155/2018/3858209 |
|
Sample: Serum |
PMID: 35037193 |
Sample: Serum |
DOI: 10.1155/2022/8251503 |
|
PMID: 36212974 |
Sample: Serum |
DOI: 10.1002/fsn3.2605 |
|
Sample: Serum |
PMID: 30483787 |
Sample: Serum |
PMID: 35429613 |
Sample: Serum |
PMID: 36367482 |
Sample: Serum |
PMID: 36041571 |
Sample: Serum |
PMID: 31654709 |
Sample: Serum |
Sample: Serum |
Sample: Serum |
PMID: 33328985 |
Sample: Serum |
Sample: Serum |
PMID: 36272568 |
Sample: Ovarian Granulosa Cells |
Sample: Cell Culture Supernatant |
DOI: 10.1039/D1FO01744F |
|
PMID: 35044398 |
Sample: Serum |
DOI: 10.2147/IJN.S302161 |
|
PMID: 34531655 |
Sample: Serum |
PMID: 36290602 |
Sample: Serum |
PMID: 35422283 |
Sample: Serum |
Sample: Serum |