GSH(Glutathione) ELISA Kit (E-EL-0026)
Add to cart
For research use only.
Product Summary
| Sensitivity | 0.94 μg/mL |
| Detection Range | 1.56-100 μg/mL |
| Sample Volume | 50 μL |
| Total Assay Time | 2 h 30 min |
| Reactivity | Universal |
| Specificity | This kit recognizes Universal GSH in samples.No significant cross-reactivity or interference between Universal GSH and analogues was observed |
| Recovery | 80%-120% |
| Sample Type | Human: Serum, EDTA plasma, heparinized plasma, Saliva, Breast milk, Urine and Stool; Mouse: Serum, EDTA plasma, Urine and Tissue homogenate; Rat: Serum, EDTA plasma, Urine and Tissue homogenate; Cell lysate, Cell culture supernatant. |
| Detection Method | Colorimetric method, ELISA, Competitive |
| Assay Type | Competitive-ELISA |
| Size | 96T / 48T / 24T / 96T*5 / 96T*10 |
| Storage | 2-8℃ |
| Expiration Date | 12 months |
Performance
| Typical data |
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only.
Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
|
||||||||||||||||||||||||||||||||||||||||||
| Sample Values |
EDTA plasma:This kit has been validated using samples from apparently healthy individuals. The data is for reference only.
Serum:This kit has been validated using samples from apparently healthy individuals. The data is for reference only.
Urine:This kit has been validated using samples from apparently healthy individuals. The data is for reference only.
|
||||||||||||||||||||||||||||||||||||||||||
| Precision |
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Universal GSH were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Universal GSH were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
|
||||||||||||||||||||||||||||||||||||||||||
| Recovery |
The recovery of Universal GSH was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
|
||||||||||||||||||||||||||||||||||||||||||
| Linearity |
Linearity of the assay was evaluated by spiking samples with high concentrations of Universal GSH and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range.
The measured values were then compared to the expected concentrations to assess the linearity of response.
|
||||||||||||||||||||||||||||||||||||||||||
| Stability |
Each kit batch is subjected to accelerated stability testing and real-time stability monitoring. Sample performance is evaluated after storage at 37 °C for 10 days to assess the impact of elevated temperature on assay reliability and reagent integrity.
|
||||||||||||||||||||||||||||||||||||||||||
Test Principle
This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with Universal GSH. During the reaction, Universal GSH in the sample or standard competes with a fixed amount of Universal GSH on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Universal GSH. Excess conjugate and unbound sample or standard are washed away, and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns from blue to yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of Universal GSH in tested samples can be calculated by comparing the OD of the samples to the standard curve.
Background
Glutathione (GSH) is a tripeptide composed of glutamate, cysteine and glycine that carries a reactive sulfhydryl group on its cysteine residue. It is the most abundant low-molecular-weight antioxidant within cells and exists in a reduced form and an oxidized disulfide form, whose ratio indicates the cellular redox state. Together these pools constitute the first line of defense for maintaining the intracellular reducing environment.
Its central function is the maintenance of redox homeostasis and antioxidant defense. GSH directly scavenges reactive oxygen and nitrogen species, regenerates other antioxidants such as ascorbate and vitamin E, and serves as a cofactor for glutathione peroxidase and glutathione S-transferase in phase II detoxification, conjugating xenobiotics and electrophiles to facilitate their excretion. Biosynthesis proceeds through two ATP-dependent reactions catalyzed by glutamate-cysteine ligase and glutathione synthetase.
Measurement of GSH is widely used in studies of oxidative stress, liver disease, toxicology and aging. Quantifying total glutathione together with the reduced-to-oxidized ratio estimates antioxidant capacity, tracks tissue injury and reflects the efficiency of detoxification. It is a practical core indicator of antioxidant defense in serum, plasma, tissue homogenates and cell lysates.
| Research Area | CellBiology , Metabolism , SignalTransduction |
-
IF:{{item.impact}}
Journal:{{item.journal}} ({{item.year}})
DOI:{{item.doi}}Reactivity:{{item.species}}
Sample Type:{{item.sample_type}}
-
Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}
No files available. Please enter the correct identification code in the search area to query the relevant documents.
| Title | Status | Valid until | Action | |
|---|---|---|---|---|
| {{v.文件名}} | {{v.status_str}} | {{v.timestamp_str}} | Download | / |
*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.
Resources
Contact with Us
Toll-free: 1-888-852-8623
Tel: 1-832-243-6086
Add:
14780 Memorial Drive, Suite 105, Houston, Texas, 77079, USA