Human DAO (Diamine Oxidase) ELISA Kit (E-EL-H6285)
Add to cart
For research use only.
Product Summary
| Sensitivity | 18.75 pg/mL |
| Detection Range | 31.25-2000 pg/mL |
| Sample Volume | 100 μL |
| Total Assay Time | 3 h 30 min |
| Reactivity | Human |
| Specificity | This kit recognizes DAO in samples.No significant cross-reactivity or interference between DAO and analogues was observed. |
| Recovery | 80%-120% |
| Sample Type | Serum, plasma and other biological fluids |
| Detection Method | Colorimetric method, ELISA, Sandwich |
| Assay Type | Sandwich-ELISA |
| Size | 96T / 48T / 24T / 96T*5 / 96T*10 |
| Storage | 2-8℃ |
| Expiration Date | 12 months |
Performance
| Typical data |
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only.
Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
|
|||||||||||||||||||||||||||||||||||||||||||||
| Precision |
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human DAO were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human DAO were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
|
|||||||||||||||||||||||||||||||||||||||||||||
| Recovery |
The recovery of Human DAO was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
|
|||||||||||||||||||||||||||||||||||||||||||||
| Linearity |
Linearity of the assay was evaluated by spiking samples with high concentrations of Human DAO and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range.
The measured values were then compared to the expected concentrations to assess the linearity of response.
|
|||||||||||||||||||||||||||||||||||||||||||||
| Stability |
Each kit batch is subjected to accelerated stability testing and real-time stability monitoring. Sample performance is evaluated after storage at 37 °C for 10 days to assess the impact of elevated temperature on assay reliability and reagent integrity.
|
|||||||||||||||||||||||||||||||||||||||||||||
Test Principle
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to DAO . Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for DAO and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain DAO , biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of DAO . You can calculate the concentration of DAO in the samples by comparing the OD of the samples to the standard curve.
Background
Diamine oxidase (DAO), also known as histaminase or amiloride-binding protein 1 (ABP1), is a copper-containing amine oxidase whose active site carries a topaquinone cofactor formed by post-translational modification of a conserved tyrosine. The enzyme is a homodimer of subunits of approximately 85 kDa, is localized to the cytoplasm and plasma membrane of epithelial cells, and requires copper for activity. DAO catalyzes the oxidative deamination of primary amines, converting histamine to imidazole acetaldehyde, ammonia and hydrogen peroxide, and it also degrades putrescine and cadaverine and, less efficiently, spermidine and spermine. Expression is most abundant in the villus tip enterocytes of the small intestine, and the enzyme is also found in the kidney, liver, placenta, decidua and seminal vesicles.
By inactivating histamine, DAO is a principal enzymatic barrier against histamine absorbed from the intestinal lumen, from food and from bacterial fermentation, and it therefore limits the local and systemic effects of this mediator. Because the enzyme is concentrated in mature enterocytes and is released into the circulation when the mucosa is damaged, serum or plasma DAO has been used as a marker of intestinal mucosal mass and integrity: values fall when villous enterocytes are lost and rise with mucosal regeneration. In pregnancy, placental DAO activity increases markedly from early gestation and contributes to the degradation of the large amounts of histamine produced by the fetoplacental unit.
Clinically and experimentally, DAO is measured in three main contexts. Reduced DAO activity is the basis of the concept of histamine intolerance, in which impaired histamine degradation leads to headache and migraine, chronic urticaria, angioedema, rhinitis, asthma, diarrhoea and hypotension after histamine-rich meals. Serum DAO is used to assess intestinal barrier damage in chemotherapy- or radiotherapy-induced mucositis, ischaemic bowel disease, inflammatory bowel disease and graft-versus-host disease, and low values have been associated with impaired gut maturation in preterm neonates. Increased DAO activity occurs in intestinal maturation, in some liver diseases and in pregnancy, and the enzyme has been proposed as a marker of intestinal integrity in colorectal disease and of the response to interventions that modulate gut permeability.
| Gene ID | 1610 |
| Uniport ID | P14920 |
| Research Area | Metabolism , SignalTransduction |
-
IF:{{item.impact}}
Journal:{{item.journal}} ({{item.year}})
DOI:{{item.doi}}Reactivity:{{item.species}}
Sample Type:{{item.sample_type}}
-
Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}
No files available. Please enter the correct identification code in the search area to query the relevant documents.
| Title | Status | Valid until | Action | |
|---|---|---|---|---|
| {{v.文件名}} | {{v.status_str}} | {{v.timestamp_str}} | Download | / |
*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.
Resources
Contact with Us
Toll-free: 1-888-852-8623
Tel: 1-832-243-6086
Add:
14780 Memorial Drive, Suite 105, Houston, Texas, 77079, USA