Human MTL(Motilin) ELISA Kit (E-EL-H2055)
Add to cart
For research use only.
Product Summary
| Sensitivity | 9.38 pg/mL |
| Detection Range | 15.63-1000 pg/mL |
| Sample Volume | 50 μL |
| Total Assay Time | 2 h 30 min |
| Reactivity | Human |
| Specificity | This kit recognizes Human MTL in samples.No significant cross-reactivity or interference between Human MTL and analogues was observed |
| Recovery | 80%-120% |
| Sample Type | Serum, EDTA plasma, heparinized plasma, Saliva, breast milk, Urine, Semen, Stool and Cell culture supernatant |
| Detection Method | Colorimetric method, ELISA, Competitive |
| Assay Type | Competitive-ELISA |
| Size | 96T / 48T / 24T / 96T*5 / 96T*10 |
| Storage | 2-8℃ |
| Expiration Date | 12 months |
Performance
| Typical data |
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only.
Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
|
||||||||||||||||||||||||||||||||||||||||||
| Sample Values |
EDTA plasma:This kit has been validated using samples from apparently healthy individuals. The data is for reference only.
Serum:This kit has been validated using samples from apparently healthy individuals. The data is for reference only.
Urine:This kit has been validated using samples from apparently healthy individuals. The data is for reference only.
|
||||||||||||||||||||||||||||||||||||||||||
| Precision |
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human MTL were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human MTL were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
|
||||||||||||||||||||||||||||||||||||||||||
| Recovery |
The recovery of Human MTL was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
|
||||||||||||||||||||||||||||||||||||||||||
| Linearity |
Linearity of the assay was evaluated by spiking samples with high concentrations of Human MTL and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range.
The measured values were then compared to the expected concentrations to assess the linearity of response.
|
||||||||||||||||||||||||||||||||||||||||||
| Stability |
Each kit batch is subjected to accelerated stability testing and real-time stability monitoring. Sample performance is evaluated after storage at 37 °C for 10 days to assess the impact of elevated temperature on assay reliability and reagent integrity.
|
||||||||||||||||||||||||||||||||||||||||||
Test Principle
This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with Human MTL. During the reaction, Human MTL in the sample or standard competes with a fixed amount of Human MTL on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Human MTL. Excess conjugate and unbound sample or standard are washed away, and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns from blue to yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of Human MTL in tested samples can be calculated by comparing the OD of the samples to the standard curve.
Background
Motilin is a 22-amino-acid peptide hormone of the motilin/ghrelin family originally identified in the mucosa of the upper small intestine and recognized as a key regulator of interdigestive gastrointestinal motility. It is synthesized and secreted by endocrine Mo cells and enterochromaffin cells of the duodenal and jejunal mucosa, and it is released cyclically into the bloodstream during fasting, so that plasma motilin oscillates in phase with the recurrent motor activity of the gut. As a small linear peptide requiring little post-translational modification, its release is rapidly suppressed by food ingestion.
The principal role of motilin is to coordinate the migrating motor complex, the housekeeping contractions that periodically sweep undigested debris, secretions and bacteria through the stomach and small intestine between meals. It acts through the G protein-coupled receptor GPR38 (MLNR) on enteric neurons and smooth muscle, whose activation elicits phase III contractions of the migrating motor complex and accelerates gastric emptying, and macrolides such as erythromycin and azithromycin act as agonists at the same receptor, offering a pharmacological route to modulate upper-gut motility.
Measurement of plasma motilin is used in studies of gastrointestinal motility and interdigestive physiology, and its concentration serves as a hormonal marker of the cyclic motor program. Assays for motilin support research on diabetic gastroparesis, functional dyspepsia, postoperative ileus and the mechanism of action of prokinetic drugs, and aid evaluation of motility disorders.
| Gene ID | 4295 |
| Uniport ID | P12872 |
| Research Area | SignalTransduction |
-
IF:{{item.impact}}
Journal:{{item.journal}} ({{item.year}})
DOI:{{item.doi}}Reactivity:{{item.species}}
Sample Type:{{item.sample_type}}
-
Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}
No files available. Please enter the correct identification code in the search area to query the relevant documents.
| Title | Status | Valid until | Action | |
|---|---|---|---|---|
| {{v.文件名}} | {{v.status_str}} | {{v.timestamp_str}} | Download | / |
*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.
Resources
Contact with Us
Toll-free: 1-888-852-8623
Tel: 1-832-243-6086
Add:
14780 Memorial Drive, Suite 105, Houston, Texas, 77079, USA