Human OCLN(Occludin) ELISA Kit (E-EL-H1073)
Add to cart
For research use only.
Product Summary
| Sensitivity | 0.1 ng/mL |
| Detection Range | 0.16-10 ng/mL |
| Sample Volume | 100 μL |
| Total Assay Time | 3 h 30 min |
| Reactivity | Human |
| Specificity | This kit recognizes Human OCLN in samples. No significant cross-reactivity or interference between Human OCLN and analogues was observed |
| Recovery | 80%-120% |
| Sample Type | Serum, EDTA plasma, heparinized plasma, breast milk, Urine and Cell lysate |
| Detection Method | Colorimetric method, ELISA, Sandwich |
| Assay Type | Sandwich-ELISA |
| Size | 96T / 48T / 24T / 96T*5 / 96T*10 |
| Storage | 2-8℃ |
| Expiration Date | 12 months |
Performance
| Typical data |
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only.
Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
|
|||||||||||||||||||||||||||||||||||||||||||||
| Sample Values |
EDTA plasma:This kit has been validated using samples from apparently healthy individuals. The data is for reference only.
Serum:This kit has been validated using samples from apparently healthy individuals. The data is for reference only.
Urine:This kit has been validated using samples from apparently healthy individuals. The data is for reference only.
|
|||||||||||||||||||||||||||||||||||||||||||||
| Precision |
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human OCLN were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human OCLN were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
|
|||||||||||||||||||||||||||||||||||||||||||||
| Recovery |
The recovery of Human OCLN was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
|
|||||||||||||||||||||||||||||||||||||||||||||
| Linearity |
Linearity of the assay was evaluated by spiking samples with high concentrations of Human OCLN and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range.
The measured values were then compared to the expected concentrations to assess the linearity of response.
|
|||||||||||||||||||||||||||||||||||||||||||||
| Stability |
Each kit batch is subjected to accelerated stability testing and real-time stability monitoring. Sample performance is evaluated after storage at 37 °C for 10 days to assess the impact of elevated temperature on assay reliability and reagent integrity.
|
|||||||||||||||||||||||||||||||||||||||||||||
Test Principle
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Human OCLN. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human OCLN and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human OCLN, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Human OCLN. You can calculate the concentration of Human OCLN in the samples by comparing the OD of the samples to the standard curve.
Background
Occludin (OCLN) is a tetraspanin integral membrane protein of epithelial and endothelial tight junctions and was one of the first tight-junction membrane proteins to be identified. The molecule contains four transmembrane segments organized in a MARVEL domain and a long cytoplasmic C-terminal tail that binds the scaffolding proteins ZO-1, ZO-2 and ZO-3 and thereby connects the junctional complex to cortical actin.
Together with claudins and junctional adhesion molecules, occludin builds and regulates the paracellular barrier, restricting the diffusion of ions, solutes and macromolecules and maintaining apico-basal cell polarity and the high transendothelial electrical resistance of barriers such as the blood-brain barrier. Its two extracellular loops contribute to selective sealing between adjacent cells, while its junctional localization is continuously remodeled by phosphorylation, ubiquitination and vesicular trafficking; loss or redistribution of the protein increases paracellular permeability.
Occludin is degraded or redistributed in inflammatory bowel disease, intestinal ischemia and infection, undermining epithelial barrier function, and the protein also serves as a co-receptor for hepatitis C virus entry into hepatocytes. This ELISA kit enables quantitative determination of occludin in serum, plasma and other biological samples, and analysis of its level, phosphorylation state and proteolytic fragments is commonly used to assess tight-junction integrity and epithelial barrier function.
| Gene ID | 100506658 |
| Uniport ID | Q16625 |
| Research Area | Cancer , SignalTransduction |
-
IF:{{item.impact}}
Journal:{{item.journal}} ({{item.year}})
DOI:{{item.doi}}Reactivity:{{item.species}}
Sample Type:{{item.sample_type}}
-
Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}
No files available. Please enter the correct identification code in the search area to query the relevant documents.
| Title | Status | Valid until | Action | |
|---|---|---|---|---|
| {{v.文件名}} | {{v.status_str}} | {{v.timestamp_str}} | Download | / |
*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.
Resources
Contact with Us
Toll-free: 1-888-852-8623
Tel: 1-832-243-6086
Add:
14780 Memorial Drive, Suite 105, Houston, Texas, 77079, USA

