Facebook

All categories

  • All categories
  • Flow Cytometry Antibodies
  • Immunoassays
  • Cell Isolation and Identification
  • Cell Health and Metabolism Assay Kits
  • Cell Culture
  • Antibodies and Reagents
  • Proteins and Peptides
Please enter the item number/product keyword!
Keyword cannot be empty !
INSERT SYMBOLS:
  • α
  • β
  • γ
  • δ
  • ε
  • ζ
  • η
  • θ
  • κ
  • μ
  • ω
  • σ
  • τ
  • λ
  • Ⅰ
  • Ⅱ
  • Ⅲ
  • Ⅳ
  • Ⅴ
  • Ⅵ
  • Ⅶ
  • Ⅷ
  • Ⅸ
  • Ⅹ
  • Ⅺ
  • Ⅻ
  • ⅩⅢ
  • ⅩⅢ
  • ⅩⅣ
  • ⅩⅤ
  • ⅩⅦ
  • ⅩⅧ
  • UP ↑
All Size Price Qty
96T $ 609.00
- +
48T $ 487.00
- +
24T $ 150.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 1.88 ng/mL
Detection Range 3.13-200 ng/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes PL in samples.No significant cross-reactivity or interference between PL and analogues was observed.
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Colorimetric method, ELISA, Sandwich
Assay Type Sandwich-ELISA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃
Expiration Date 12 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
200 2.069 2.129 2.099 2.021
100 1.486 1.458 1.472 1.394
50 0.939 0.915 0.927 0.849
25 0.446 0.460 0.453 0.375
12.5 0.287 0.269 0.278 0.200
6.25 0.169 0.173 0.171 0.093
3.13 0.120 0.128 0.124 0.046
0 0.075 0.081 0.078 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human PL were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human PL were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 9.930 24.330 68.010 10.710 23.200 70.300
Standard deviation 0.600 1.520 3.050 0.770 1.920 4.470
CV(%) 6.060 6.260 4.490 7.220 8.270 6.360
Recovery
The recovery of Human PL was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Cell culture media (n=8) 87-100 94
Serum (n=8) 88-104 95
EDTA plasma (n=8) 96-107 101
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human PL and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 87-100 96-111 96-113
Average 93 103 104
1:4 Range 83-94 95-111 96-109
Average 89 102 101
1:8 Range 85-97 96-112 95-112
Average 91 104 102
Stability
Each kit batch is subjected to accelerated stability testing and real-time stability monitoring. Sample performance is evaluated after storage at 37 °C for 10 days to assess the impact of elevated temperature on assay reliability and reagent integrity.
/ Variation range of 37°C mean
concentration / 2-8°C mean
Sample 1(n=16) 92.13-99.13
Sample 2(n=16) 87.51-101.09
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to PL . Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for PL and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain PL , biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of PL . You can calculate the concentration of PL in the samples by comparing the OD of the samples to the standard curve.
Placental lactogen (PL), also known as human chorionic somatomammotropin, is a 191-amino-acid single-chain polypeptide of about 22 kDa that belongs to the growth hormone/prolactin family and shares roughly 85% sequence identity with growth hormone. It is produced almost exclusively by the syncytiotrophoblast of the placenta, appears in maternal serum from about the fifth week of gestation and rises in proportion to placental mass, reaching several micrograms per millilitre at term. PL binds the prolactin receptor and, with lower affinity, the growth hormone receptor, thereby combining lactogenic and somatogenic activities. Its principal role is maternal metabolic adaptation to pregnancy: it induces insulin resistance, reduces maternal glucose uptake and stimulates lipolysis, sparing glucose and amino acids for the fetus, while it also promotes mammary gland development. Because maternal PL concentration mirrors functional trophoblast mass, it is used to assess placental function. Values are low in placental insufficiency, intrauterine growth restriction and some hypertensive disorders of pregnancy, and elevated in multiple pregnancy, hydatidiform mole, choriocarcinoma and some cases of maternal diabetes. PL also serves as a marker of trophoblastic tumours.
Gene ID 1442
Uniport ID P0DML2
Research Area DevelopmentalBiology , SignalTransduction
Product Recommendations for Literature Synchronization

Note: Data for this module come from published literature that cites this product, displaying other products used together in the same research paper.

Reactivity

{{relatedElisaPage.numTotal}} Results

  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定