Micro-Sample

Mini Sample Human DAO ( Diamine Oxidase ) ELISA Kit (E-MSEL-H0022)

All Size Price Qty
96T $ 510.00
- +
48T $ 408.00
- +
24T $ 150.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 0.47 ng/mL
Detection Range 0.78-50 ng/mL
Sample Volume 25 μL
Manual Operation Time 1 h
Total Assay Time 3 h 30 min
Reactivity Human
Specificity This kit recognizes DAO in samples.No significant cross-reactivity or interference between DAO and analogues was observed.
Recovery 80%-120%
Sample Type Serum, plasma and other biological fluids
Detection Method Colorimetric method, ELISA, Sandwich
Assay Type Sandwich-ELISA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃
Expiration Date 12 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD Corrected OD
50 2.501 2.595 2.548 2.471
25 1.630 1.662 1.646 1.569
12.5 0.919 0.899 0.909 0.832
6.25 0.509 0.503 0.506 0.429
3.13 0.264 0.284 0.274 0.197
1.56 0.168 0.170 0.169 0.092
0.78 0.125 0.133 0.129 0.052
0 0.078 0.076 0.077 -
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Human DAO were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Human DAO were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 2.440 4.980 24.310 2.470 4.910 22.340
Standard deviation 0.110 0.230 1.610 0.160 0.340 1.590
CV(%) 4.560 4.670 6.610 6.300 6.890 7.110
Recovery
The recovery of Human DAO was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 90-103 96
EDTA plasma (n=8) 89-103 95
Cell culture media (n=8) 86-101 93
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Human DAO and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 91-106 88-98 96-111
Average 98 93 103
1:4 Range 88-104 84-94 92-103
Average 96 89 98
1:8 Range 91-104 89-103 94-109
Average 97 94 101
Stability
Each kit batch is subjected to accelerated stability testing and real-time stability monitoring. Sample performance is evaluated after storage at 37 °C for 10 days to assess the impact of elevated temperature on assay reliability and reagent integrity.
/ Variation range of 37°C mean
concentration / 2-8°C mean
Sample 1(n=16) 101.2-108.97
Sample 2(n=16) 109.29-112.37
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to DAO . Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for DAO and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain DAO , biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of DAO . You can calculate the concentration of DAO in the samples by comparing the OD of the samples to the standard curve.
Diamine oxidase (DAO), also known as histaminase or amiloride-binding protein 1, is a copper-containing amine oxidase whose active site carries a topaquinone cofactor. It is a homodimer of approximately 85 kDa subunits located in the cytoplasm and plasma membrane of epithelial cells, and it catalyses the oxidative deamination of primary amines, converting histamine to imidazole acetaldehyde, ammonia and hydrogen peroxide while also degrading putrescine and cadaverine. DAO is expressed most abundantly in the villus tip enterocytes of the small intestine and is also present in kidney, liver and placenta. By inactivating histamine absorbed from the gut lumen, food and bacterial fermentation, it acts as a major enzymatic barrier limiting the local and systemic effects of this mediator. Because the enzyme is concentrated in mature enterocytes and is released into the circulation when the mucosa is damaged, serum DAO activity is used as a marker of intestinal mucosal mass and barrier integrity: it falls when villous cells are lost and rises with mucosal regeneration. Clinically, reduced DAO activity underlies histamine intolerance, in which impaired histamine degradation causes headache, urticaria, angioedema, rhinitis, asthma, diarrhoea and hypotension after histamine-rich meals. DAO is also measured to assess mucosal injury in chemotherapy-induced mucositis, ischaemic bowel disease, inflammatory bowel disease and graft-versus-host disease.
Gene Alias DAO
Gene ID 1610
Uniport ID P14920
Protein Alias DAO
Research Area Metabolism , SignalTransduction
Product Recommendations for Literature Synchronization

Note: Data for this module come from published literature that cites this product, displaying other products used together in the same research paper.

Reactivity

{{relatedElisaPage.numTotal}} Results

Mini Sample Human DAO ( Diamine Oxidase ) ELISA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定