Mouse cTnT/TNNT2(Troponin T Type 2, Cardiac) ELISA Kit (E-EL-M1801)

All Size Price Qty
96T $ 609.00
- +
48T $ 487.00
- +
24T $ 150.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 9.38 pg/mL
Detection Range 15.63-1000 pg/mL
Sample Volume 100 μL
Total Assay Time 3 h 30 min
Reactivity Mouse
Specificity This kit recognizes Mouse cTnT/TNNT2 in samples. No significant cross-reactivity or interference between Mouse cTnT/TNNT2 and analogues was observed
Recovery 80%-120%
Sample Type Serum, EDTA plasma, Tissue homogenate and Cell lysate
Detection Method Colorimetric method, ELISA, Sandwich
Assay Type Sandwich-ELISA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃
Expiration Date 12 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
pg/mL OD1 OD2 Mean OD Corrected OD
1000 2.285 2.267 2.276 2.202
500 1.564 1.508 1.536 1.462
250 0.942 0.956 0.949 0.875
125 0.522 0.506 0.514 0.440
62.5 0.274 0.256 0.265 0.191
31.25 0.165 0.167 0.166 0.092
15.63 0.123 0.125 0.124 0.050
0 0.078 0.070 0.074 -
Sample Values
EDTA plasma:This kit has been validated using samples from apparently healthy individuals. The data is for reference only.
Serum:This kit has been validated using samples from apparently healthy individuals. The data is for reference only.
Sample Type Sample Size Range Recommended Dilution Factor
Mouse EDTA plasma 30 17.46-586.91 pg/mL Undiluted
Mouse Serum 30 33.81-436.83 pg/mL Undiluted
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Mouse cTnT were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Mouse cTnT were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(pg/mL) 47.000 147.590 399.980 49.090 145.150 414.600
Standard deviation 2.220 6.920 23.760 3.430 11.350 31.760
CV(%) 4.720 4.690 5.940 6.980 7.820 7.660
Recovery
The recovery of Mouse cTnT was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Cell culture media (n=8) 88-103 95
Serum (n=8) 86-97 92
EDTA plasma (n=8) 88-102 94
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Mouse cTnT and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 88-101 85-97 95-111
Average 93 92 102
1:4 Range 86-100 87-97 91-107
Average 92 92 98
1:8 Range 80-95 82-96 93-108
Average 87 88 100
Stability
Each kit batch is subjected to accelerated stability testing and real-time stability monitoring. Sample performance is evaluated after storage at 37 °C for 10 days to assess the impact of elevated temperature on assay reliability and reagent integrity.
/ Variation range of 37°C mean
concentration / 2-8°C mean
Sample 1(n=16) 87.13-107.65
Sample 2(n=16) 102.17-107.97
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Mouse cTnT/TNNT2. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse cTnT/TNNT2 and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse cTnT/TNNT2, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Mouse cTnT/TNNT2. You can calculate the concentration of Mouse cTnT/TNNT2 in the samples by comparing the OD of the samples to the standard curve.
Cardiac troponin T (cTnT) is encoded by TNNT2, whose expression is restricted to cardiomyocytes by cardiac-specific transcriptional programmes. cTnT is the tropomyosin-binding subunit of the thin-filament troponin complex and transmits the calcium-dependent conformational change of troponin C through tropomyosin to the actin filament, thereby switching contraction on and off in cardiac muscle. Acting together with troponin I and troponin C, cTnT sets myofilament calcium sensitivity and participates in cooperative activation of the thin filament. In healthy subjects circulating cardiac cTnT is extremely low, but loss of cell integrity releases the small cytosolic pool rapidly, after which sustained degradation of the structurally bound pool maintains elevation for days, with release kinetics and peak concentration reflecting the extent of damage. TNNT2 mutations cause hypertrophic and dilated cardiomyopathy, underscoring its central importance for cardiac mechanics and for inherited heart muscle disease. Elevated cTnT is a widely accepted marker of myocardial injury, essential for diagnosis of myocardial infarction, for risk stratification in acute coronary syndromes and for detecting drug-induced cardiotoxicity. Quantitative determination of cardiac troponin T supports cardiovascular research in infarction, ischaemia-reperfusion, genetic cardiomyopathy and toxicology models, and remains an important basis for evaluating myocardial damage in experimentally treated animals.
Gene ID 21956
Uniport ID P50752
Research Area Cancer , Cardiovascular , SignalTransduction , Stemcells
Product Recommendations for Literature Synchronization

Note: Data for this module come from published literature that cites this product, displaying other products used together in the same research paper.

Reactivity

{{relatedElisaPage.numTotal}} Results

Mouse cTnT/TNNT2(Troponin T Type 2, Cardiac) ELISA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定