Mouse LEPR(Leptin Receptor) ELISA Kit (E-EL-M3040)
Add to cart
For research use only.
Product Summary
| Sensitivity | 1.88 ng/mL |
| Detection Range | 3.13-200 ng/mL |
| Sample Volume | 100 μL |
| Total Assay Time | 3 h 30 min |
| Reactivity | Mouse |
| Specificity | This kit recognizes Mouse LEPR in samples.No significant cross-reactivity or interference between Mouse LEPR and analogues was observed |
| Recovery | 80%-120% |
| Sample Type | Serum, EDTA plasma, Tissue homogenate and Cell lysate |
| Detection Method | Colorimetric method, ELISA, Sandwich |
| Assay Type | Sandwich-ELISA |
| Size | 96T / 48T / 24T / 96T*5 / 96T*10 |
| Storage | 2-8℃ |
| Expiration Date | 12 months |
Performance
| Typical data |
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only.
Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
|
|||||||||||||||||||||||||||||||||||||||||||||
| Sample Values |
EDTA plasma:This kit has been validated using samples from apparently healthy individuals. The data is for reference only.
Serum:This kit has been validated using samples from apparently healthy individuals. The data is for reference only.
|
|||||||||||||||||||||||||||||||||||||||||||||
| Precision |
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Mouse LEPR were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Mouse LEPR were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
|
|||||||||||||||||||||||||||||||||||||||||||||
| Recovery |
The recovery of Mouse LEPR was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
|
|||||||||||||||||||||||||||||||||||||||||||||
| Linearity |
Linearity of the assay was evaluated by spiking samples with high concentrations of Mouse LEPR and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range.
The measured values were then compared to the expected concentrations to assess the linearity of response.
|
|||||||||||||||||||||||||||||||||||||||||||||
| Stability |
Each kit batch is subjected to accelerated stability testing and real-time stability monitoring. Sample performance is evaluated after storage at 37 °C for 10 days to assess the impact of elevated temperature on assay reliability and reagent integrity.
|
|||||||||||||||||||||||||||||||||||||||||||||
Test Principle
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Mouse LEPR. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Mouse LEPR and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Mouse LEPR, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Mouse LEPR. You can calculate the concentration of Mouse LEPR in the samples by comparing the OD of the samples to the standard curve.
Background
Leptin receptor (LEPR), also known as the obesity receptor, belongs to the gp130 family of class I cytokine receptors and mediates the effects of leptin on body weight and energy balance. Alternative splicing produces several membrane-bound isoforms with short or long cytoplasmic tails as well as a soluble form generated by ectodomain shedding; the long isoform is abundant in the hypothalamus and carries the intracellular motifs required for complete signal transduction.
Upon leptin binding, LEPR activates the associated JAK2 kinase and downstream STAT3, STAT5 and ERK pathways, producing transcriptional programmes that suppress appetite, increase thermogenesis and energy expenditure and permit normal pubertal maturation. Through the same cascades the receptor coordinates neuroendocrine axes, including the hypothalamic-pituitary-gonadal and thyroid axes, influences lipid metabolism in peripheral tissues and supports lymphopoiesis and immune competence. Mutations in LEPR or in leptin itself cause severe early-onset obesity with hyperphagia, and the obesity of db/db mice results from defective receptor signalling.
Because the leptin system integrates nutritional status with neuroendocrine and immune function, quantitative measurement of LEPR, especially the soluble isoform that modulates leptin bioavailability and transport, is relevant to research on obesity, metabolic syndrome, type 2 diabetes, hypothalamic amenorrhoea and reproductive disorders.
| Gene ID | 16847 |
| Uniport ID | P48356 |
| Research Area | Cancer , Cardiovascular , Metabolism , SignalTransduction |
-
IF:{{item.impact}}
Journal:{{item.journal}} ({{item.year}})
DOI:{{item.doi}}Reactivity:{{item.species}}
Sample Type:{{item.sample_type}}
-
Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}
No files available. Please enter the correct identification code in the search area to query the relevant documents.
| Title | Status | Valid until | Action | |
|---|---|---|---|---|
| {{v.文件名}} | {{v.status_str}} | {{v.timestamp_str}} | Download | / |
*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.
Resources
Contact with Us
Toll-free: 1-888-852-8623
Tel: 1-832-243-6086
Add:
14780 Memorial Drive, Suite 105, Houston, Texas, 77079, USA