Facebook

All categories

  • All categories
  • Flow Cytometry Antibodies
  • Immunoassays
  • Cell Isolation and Identification
  • Cell Health and Metabolism Assay Kits
  • Cell Culture
  • Antibodies and Reagents
  • Proteins and Peptides
Please enter the item number/product keyword!
Keyword cannot be empty !
INSERT SYMBOLS:
  • α
  • β
  • γ
  • δ
  • ε
  • ζ
  • η
  • θ
  • κ
  • μ
  • ω
  • σ
  • τ
  • λ
  • Ⅰ
  • Ⅱ
  • Ⅲ
  • Ⅳ
  • Ⅴ
  • Ⅵ
  • Ⅶ
  • Ⅷ
  • Ⅸ
  • Ⅹ
  • Ⅺ
  • Ⅻ
  • ⅩⅢ
  • ⅩⅢ
  • ⅩⅣ
  • ⅩⅤ
  • ⅩⅦ
  • ⅩⅧ
  • UP ↑
All Size Price Qty
96T $ 609.00
- +
48T $ 487.00
- +
24T $ 150.00
- +
96T*5 Inquire /
96T*10 Inquire /
Add to cart

For research use only.

Product Summary
Sensitivity 0.1 ng/mL
Detection Range 0.16-10 ng/mL
Sample Volume 50 μL
Total Assay Time 2 h 30 min
Reactivity Rat
Specificity This kit recognizes Rat GHRL in samples.No significant cross-reactivity or interference between Rat GHRL and analogues was observed
Recovery 80%-120%
Sample Type Serum, EDTA plasma, Tissue homogenate and Cell lysate
Detection Method Colorimetric method, ELISA, Competitive
Assay Type Competitive-ELISA
Size 96T / 48T / 24T / 96T*5 / 96T*10
Storage 2-8℃
Expiration Date 12 months
Typical data
The following data was generated by the Quality Control Department, under controlled laboratory conditions (ambient temperature: 18-25 °C, relative humidity: 35-75%) using standardized procedures (TMB reaction at 37 °C in the dark for 15 minutes, followed by termination and OD measurement). These values are provided for reference only. Actual results may vary due to differences in laboratory conditions, operator technique, and equipment. Users are required to generate a standard curve using their own experimental data.
ng/mL OD1 OD2 Mean OD
10 0.158 0.164 0.161
5 0.237 0.227 0.232
2.5 0.378 0.380 0.379
1.25 0.563 0.577 0.570
0.63 0.937 0.897 0.917
0.31 1.311 1.255 1.283
0.16 1.584 1.508 1.546
0 2.051 2.141 2.096
Precision
Intra-assay Precision (Within-run Precision): Three samples representing low, mid, and high concentrations of Rat GHRL were tested 20 times on a single plate.
Inter-assay Precision (Between-run Precision): Three samples representing low, mid, and high concentrations of Rat GHRL were tested on three separate plates, with 20 replicates per plate, to assess variability among assays.
/ Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
Numbers 20 20 20 20 20 20
Mean(ng/mL) 0.470 1.610 4.040 0.470 1.760 4.170
Standard deviation 0.030 0.070 0.280 0.030 0.140 0.290
CV(%) 6.100 4.630 6.850 6.160 8.070 6.930
Recovery
The recovery of Rat GHRL was evaluated by spiking samples at low, mid, and high concentrations across the assay range in various sample matrices.
The assay performance was assessed by comparing the measured concentrations to the expected spiked amounts to determine the percent recovery.
Sample Type Range (%) Average Recovery(%)
Serum (n=8) 92-103 97
EDTA plasma (n=8) 85-101 92
Cell culture media (n=8) 93-106 98
Linearity
Linearity of the assay was evaluated by spiking samples with high concentrations of Rat GHRL and performing serial dilutions using Standard & Sample Diluent to produce concentrations spanning the assay's dynamic range. The measured values were then compared to the expected concentrations to assess the linearity of response.
/ / Cell culture media
(n=5)
EDTA plasma
(n=5)
Serum
(n=5)
1:2 Range 96-111 88-100 86-99
Average 104 93 91
1:4 Range 95-112 93-107 86-98
Average 102 98 93
1:8 Range 93-105 91-104 90-103
Average 100 97 95
Stability
Each kit batch is subjected to accelerated stability testing and real-time stability monitoring. Sample performance is evaluated after storage at 37 °C for 10 days to assess the impact of elevated temperature on assay reliability and reagent integrity.
/ Variation range of 37°C mean
concentration / 2-8°C mean
Sample 1(n=16) 93.7-110.63
Sample 2(n=16) 90.33-101.29
This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with Rat GHRL. During the reaction, Rat GHRL in the sample or standard competes with a fixed amount of Rat GHRL on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Rat GHRL. Excess conjugate and unbound sample or standard are washed away, and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns from blue to yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of Rat GHRL in tested samples can be calculated by comparing the OD of the samples to the standard curve.
S100B is a member of the S100 family of small calcium-binding proteins and contains two EF-hand calcium-binding motifs. It exists as a homodimer of subunits of roughly 10-12 kDa, and calcium binding triggers a conformational change that exposes a hydrophobic interface for target protein interaction. S100B participates in metabolism, cell motility, proliferation and calcium signaling, and in the nervous system it is highly expressed and constitutively released by astrocytes. Intracellular S100B regulates enzyme activity, cytoskeletal dynamics and calcium homeostasis, whereas extracellular S100B acts in a concentration-dependent manner. At nanomolar concentrations it is neurotrophic, promoting neurite outgrowth, neuronal survival and protection against oxidative injury, while micromolar concentrations, often reached after cell damage, induce apoptosis and neuroinflammation through the receptor for advanced glycation end products (RAGE), making it a marker of astrocyte activation. S100B enters the cerebrospinal fluid and, when the blood-brain barrier is disrupted, the bloodstream, where its concentration reflects glial injury and barrier dysfunction; it has therefore been studied as a biomarker of traumatic brain injury, stroke, cardiac arrest and neurodegenerative disease. This ELISA kit enables quantitative determination of rat S100B in serum, plasma and cerebrospinal fluid.
Uniport ID Q9QYH7 aa:24-51
Research Area Cancer , Cardiovascular , Metabolism , Neuroscience , SignalTransduction
Rat GHRL(Ghrelin) ELISA Kit - procedures
  • IF:{{item.impact}}

    Journal:{{item.journal}} ({{item.year}})

    DOI:{{item.doi}}

    Reactivity:{{item.species}}

    Sample Type:{{item.sample_type}}

Species

{{relatedElisaPage.numTotal}} Results

  • Q{{(FAQpage.currentPage - 1)*pageSize+index+1}}:{{item.name}}

No files available. Please enter the correct identification code in the search area to query the relevant documents.

empty
Product Information
Title Status Valid until Action
{{v.文件名}} {{v.status_str}} {{v.timestamp_str}} Download /

*Note:Please download the relevant files within the validity period. After expiration, file preview and download will not be available on the page.

确定