Current Position:Home>>Kits>>ELISA Kits>> Mouse IgE(Immunoglobulin E) ELISA Kit
Cat.No.:E-EL-M3034
Welcome to order from local distributors.
Add to cart Bulk requestFor research use only. Order now, ship in 3 days
Assay type | Sandwich-ELISA |
Format | 96T/48T/24 |
Assay time | 3.5h |
Detection range | 125.00-8000 ng/mL |
Sensitivity | 75.00 ng/mL |
Sample type &Sample volume | serum, plasma and other biological fluids; 100μL |
Specificity | This kit recognizes Mouse IgE in samples. No significant cross-reactivity or interference between Mouse IgE and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are < 10%. |
Application | This ELISA kit applies to the in vitro quantitative determination of Mouse IgE concentrations in serum, plasma and other biological fluids. |
Item | Specifications | Storage |
---|---|---|
Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips
48T: 8 wells ×6 strips |
-20℃, 12 months |
Reference Standard | 96T: 2 vials
48T: 1 vial |
|
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
|
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
-20℃(Protect from light), 12 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 12 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent | 1 vial, 10 mL | 2-8℃(Protect from light) |
Stop Solution | 1 vial, 10 mL | 2-8°C |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Mouse IgE were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Mouse IgE were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (ng/mL) | 382.47 | 858.80 | 3319.11 | 351.27 | 946.20 | 3588.32 |
Standard deviation | 21.34 | 40.54 | 153.34 | 19.81 | 46.65 | 191.98 |
CV (%) | 5.58 | 4.72 | 4.62 | 5.64 | 4.93 | 5.35 |
The recovery of Mouse IgE spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
---|---|---|
Serum(n=8) | 101-111 | 104 |
EDTA plasma (n=8) | 86-97 | 93 |
Cell culture media (n=8) | 94-108 | 102 |
Samples were spiked with high concentrations of Mouse IgE and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Synonyms | IgE |
Research Area | Immunology |
1. Add 100μL standard or sample to the wells. Incubate for 90 min at 37°C |
|
2. Discard the liquid, immediately add 100μL Biotinylated Detection Ab working solution to each well. Incubate for 60 min at 37°C |
|
3. Aspirate and wash the plate for 3 times |
|
4. Add 100μL HRP conjugate working solution. Incubate for 30 min at 37°C. Aspirate and wash the plate for 5 times |
|
5. Add 90μL Substrate Reagent. Incubate for 15 min at 37°C |
|
6. Add 50μL Stop Solution |
|
7. Read the plate at 450nm immediately. Calculation of the results |
Sample: Serum |
PMID: 33855746 |
Sample: Serum |
PMID: 30823938 |
Sample: Plasma |
DOI: 10.1159/000528634 |
|
Sample: Serum |
Sample: Serum |
PMID: 34256821 |
Sample: Serum |
PMID: 34488852 |
Sample: Serum |
PMID: 33166807 |
Sample: Serum |
DOI: 10.1038/srep42655 |
|
Sample: Bronchoalveolar Lavage Fluid,Serum |
PMID: 35143934 |
Sample: Lung |
DOI: 10.1039/D1FO00083G |
|
PMID: 34031673 |
Sample: Serum |
PMID: 36179418 |
Sample: Serum |
DOI: 10.1111/bph.15913 |
|
Sample: Serum |
PMID: 35780899 |
Sample: Plasma |
M***********dSubmitted [ Aug 28 2023 ]
Asked: What dilution should be taken for serum samples?
Reply
adminSubmitted [ Aug 28 2023 ]
Answered: For E-EL-M3034 kit, it is recommended to dilute serum samples at 1-10 folds to test.