Current Position:Home>>Kits>>ELISA Kits>> MS Mouse LEP(Leptin) ELISA Kit
Cat.No.:E-MSEL-M0033
Welcome to order from local distributors.
Add to cart Bulk requestFor research use only. Order now, ship in 3 days
Assay type | Sandwich-ELISA |
Format | 48T/96T/96 |
Assay time | 3.5h |
Detection range | 0.63-40 ng/mL |
Sensitivity | 0.38 ng/mL |
Sample type &Sample volume | serum, plasma and other biological fluids; 25μL |
Specificity | This kit recognizes Mouse LEP in samples. No significant cross-reactivity or interference between Mouse LEP and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are < 10%. |
Application | This ELISA kit applies to the in vitro quantitative determination of Mouse LEP concentrations in serum, plasma and other biological fluids. |
Item | Specifications | Storage |
---|---|---|
Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips
48T: 8 wells ×6 strips |
-20℃, 6 months |
Reference Standard | 96T: 2 vials
48T: 1 vial |
|
Concentrated Biotinylated Detection Ab (50×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
|
Concentrated HRP Conjugate (50×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
-20℃(Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent | 1 vial, 10 mL | 2-8℃(Protect from light) |
Stop Solution | 1 vial, 10 mL | 2-8°C |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Mouse LEP were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Mouse LEP were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (ng/mL) | 2.13 | 5.51 | 15.51 | 2.27 | 5.09 | 16.44 |
Standard deviation | 0.11 | 0.24 | 0.79 | 0.13 | 0.28 | 0.61 |
CV (%) | 5.15 | 4.38 | 5.12 | 5.93 | 5.59 | 3.73 |
The recovery of Mouse LEP spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
---|---|---|
Serum(n=8) | 93-108 | 100 |
EDTA plasma (n=8) | 93-108 | 101 |
Cell culture media (n=8) | 90-105 | 96 |
Samples were spiked with high concentrations of Mouse LEP and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Database Links | SwissProt:
P41160
|
Synonyms | LEPD, OB, OBS, Obesity Homolog |
Research Area | Cancer, Cardiovascular, Metabolism, Neuroscience, Signal transduction, Stem cells |
Sample: serum |
PMID: 32222773 |
Sample: serum |
PMID: 33070067 |
Sample: Serum |
PMID: 31891846 |
Sample: Serum |
DOI: 10.3390/nu13031017 |
|
PMID: 33801119 |
Sample: Serum |
PMID: 33663304 |
Sample: Serum |
DOI: 10.3390/biom10101454 |
|
PMID: 33080865 |
Sample: Serum |
DOI: 10.1039/D0FO01405B |
|
PMID: 32815965 |
Sample: Serum |
DOI: 10.3390/ijms21145121 |
|
Sample: serum |
Sample: Serum |
Sample: plasma |
PMID: 32652086 |
Sample: Serum |
PMID: 31254565 |
Sample: Serum |
Sample: serum |
Sample: Serum |
Sample: 3T3-L1 cell |
DOI: 10.1155/2021/8367802 |
|
PMID: 33643424 |
Sample: Plasma |
DOI: 10.14814/phy2.13271 |
|
Sample: serum |