Current Position:Home>>Kits>>ELISA Kits>> Rat ALB(Albumin) ELISA Kit
Cat.No.:E-EL-R0362
Welcome to order from local distributors.
Add to cart Bulk requestFor research use only. Order now, ship in 3 days
Assay type | Sandwich-ELISA |
Format | 96T/48T |
Assay time | 3.5h |
Detection range | 3.13-200 μg/mL |
Sensitivity | 1.88 μg/mL |
Sample type &Sample volume | serum, plasma and other biological fluids; 100μL |
Specificity | This kit recognizes Rat ALB in samples. No significant cross-reactivity or interference between Rat ALB and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are < 10%. |
Application | This ELISA kit applies to the in vitro quantitative determination of Rat ALB concentrations in serum, plasma and other biological fluids. |
Item | Specifications | Storage |
---|---|---|
Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips
48T: 8 wells ×6 strips |
-20℃, 12 months |
Reference Standard | 96T: 2 vials
48T: 1 vial |
|
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
|
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
-20℃(Protect from light), 12 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 12 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent | 1 vial, 10 mL | 2-8℃(Protect from light) |
Stop Solution | 1 vial, 10 mL | 2-8°C |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Rat ALB were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Rat ALB were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (μg/mL) | 9.90 | 25.50 | 76.00 | 9.80 | 23.30 | 78.50 |
Standard deviation | 0.50 | 1.20 | 3.60 | 0.50 | 1.20 | 2.70 |
CV (%) | 5.05 | 4.71 | 4.74 | 5.10 | 5.15 | 3.44 |
The recovery of Rat ALB spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
---|---|---|
Serum(n=8) | 86-96 | 91 |
EDTA plasma (n=8) | 86-100 | 91 |
Cell culture media (n=8) | 95-107 | 101 |
Samples were spiked with high concentrations of Rat ALB and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Database Links | SwissProt:
P02770
|
Research Area | Cancer, Cardiovascular, Metabolism, Developmental biology, Signal transduction, Stem cells |
1. Add 100μL standard or sample to the wells. Incubate for 90 min at 37°C |
|
2. Discard the liquid, immediately add 100μL Biotinylated Detection Ab working solution to each well. Incubate for 60 min at 37°C |
|
3. Aspirate and wash the plate for 3 times |
|
4. Add 100μL HRP conjugate working solution. Incubate for 30 min at 37°C. Aspirate and wash the plate for 5 times |
|
5. Add 90μL Substrate Reagent. Incubate for 15 min at 37°C |
|
6. Add 50μL Stop Solution |
|
7. Read the plate at 450nm immediately. Calculation of the results |
DOI: 10.1002/ddr.21581 |
|
Sample: Liver |
DOI: 10.1111/jfbc.14058 |
|
PMID: 34981526 |
Sample: Serum |
DOI: 10.3390/ani12070932 |
|
PMID: 35405920 |
Sample: Serum |
PMID: 33181259 |
Sample: Serum |
Sample: Liver,Ileum |
Sample: Urine |
PMID: 35534645 |
Sample: Urinary |
PMID: 35642843 |
Sample: Urine |
DOI: 10.1039/D1FO02445K |
|
PMID: 35531774 |
Sample: Urinary |
PMID: 36056427 |
Sample: Urine |