Current Position:Home>>Kits>>ELISA Kits>> Rat FETUA(Fetuin A) ELISA Kit
Cat.No.:E-EL-R2451
Welcome to order from local distributors.
Add to cart Bulk requestFor research use only. Order now, ship in 3 days
Assay type | Sandwich-ELISA |
Format | 96T/48T |
Assay time | 3.5h |
Detection range | 6.25-400 ng/mL |
Sensitivity | 3.75 ng/mL |
Sample type &Sample volume | serum, plasma and other biological fluids; 100μL |
Specificity | This kit recognizes Rat FETUA in samples. No significant cross-reactivity or interference between Rat FETUA and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are < 10%. |
Application | This ELISA kit applies to the in vitro quantitative determination of Rat FETUA concentrations in serum, plasma and other biological fluids. |
Item | Specifications | Storage |
---|---|---|
Micro ELISA Plate(Dismountable) | 96T: 8 wells ×12 strips
48T: 8 wells ×6 strips |
-20℃, 6 months |
Reference Standard | 96T: 2 vials
48T: 1 vial |
|
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
|
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL
48T: 1 vial, 60 μL |
-20℃(Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent | 1 vial, 10 mL | 2-8℃(Protect from light) |
Stop Solution | 1 vial, 10 mL | 2-8°C |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy |
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Rat FETUA were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Rat FETUA were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
---|---|---|---|---|---|---|
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (ng/mL) | 21.49 | 52.33 | 177.04 | 22.43 | 49.95 | 190.26 |
Standard deviation | 1.21 | 2.86 | 6.59 | 1.43 | 2.53 | 9.97 |
CV (%) | 5.63 | 5.47 | 3.72 | 6.38 | 5.07 | 5.24 |
The recovery of Rat FETUA spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
---|---|---|
Serum(n=8) | 93-107 | 98 |
EDTA plasma (n=8) | 92-105 | 99 |
Cell culture media (n=8) | 95-110 | 100 |
Samples were spiked with high concentrations of Rat FETUA and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Synonyms | AHSG, A2HS, AHS, HSGA, alpha-2-HS-glycoprotein |
Research Area | Cardiovascular, Metabolism, Neuroscience |
![]() |
1. Add 100μL standard or sample to the wells. Incubate for 90 min at 37°C |
![]() |
2. Discard the liquid, immediately add 100μL Biotinylated Detection Ab working solution to each well. Incubate for 60 min at 37°C |
![]() |
3. Aspirate and wash the plate for 3 times |
![]() |
4. Add 100μL HRP conjugate working solution. Incubate for 30 min at 37°C. Aspirate and wash the plate for 5 times |
![]() |
5. Add 90μL Substrate Reagent. Incubate for 15 min at 37°C |
![]() |
6. Add 50μL Stop Solution |
![]() |
7. Read the plate at 450nm immediately. Calculation of the results |
From now on, if you have published a paper by using any of our products since 1/1/2019, fill out the “Elabscience Publication Reward Application Form”carefully and send it to orders@elabscience.com, we will get back to you with the reward after we confirm it ASAP!
DOI: 10.1111/acel.13377 |
|
PMID: 33969611 |
Sample: Serum |
M*****aSubmitted [ Jun 29 2022 ]
Asked: I received email that says \"your question about the product Rat FETUA(Fetuin A) ELISA Kit has been replied\" but I don\'t know how to check the answer. Please tell me how to do it.
Reply
adminSubmitted [ Jun 29 2022 ]
Answered: We have received your feedback about the problem. The problem of no signal in the sample you complained belongs to the after-sales problem. We hope you can fill in the after-sales registration form to help us understand the relevant information. We would be grateful if you could provide additional sample information. 1. Are your rat serum samples diluted for testing? 2. How are your rat serum samples collected and preserved? How long did it last? 3. What is the disease model you are studying? We will send a sheet by e-mail. Pls kindly check it.
K*********iSubmitted [ Jun 29 2022 ]
Asked: I tried to calculate fetuin-a concentration in rat serum by using this kit. Although signals of standard sample was detected signals of rat serum was not detected at all. Could you tell me your thought of the reason why signals of rat serum was not detected?
Reply
adminSubmitted [ Jun 29 2022 ]
Answered: Please obtain the after-sales registration form from the dealer who sold the kit to you and fill in the kit number, lot number, relevant experimental operation information and original data of the kit. We will help you solve the corresponding problems later.